Logo
Aquamatic DP Parker Watermakers 1024 Square

Aqua Matic DP V2

The Aqua Matic DP V2 from Parker WP is a revolutionary water filtration system ensuring pure, residue-free water for drinking and cooking. It offers a versatile solution for any space, seamlessly converting from modular to compact.

This system is for you looking for a:

  • Adjustable water production rate
  • Easy installation
  • Automatic operation
  • Energy-efficiency.

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Easy Maintenance Design and 5 Other Beneficial Features for You

The Aqua Matic DP V2 has several features that benefits you, however the key features you should know about is:

Advanced Technology

The Aqua Matic DP V2 utilizes state-of-the-art technology for water purification, ensuring the water you drink is free of contaminants and safe to consume.

 

Multi-Stage Filtration

The multi-stage filtration process ensures that every drop of water is meticulously purified. This process includes several purification stages to eliminate different impurities, leaving no residue behind.

 

Versatile Design

The Aqua Matic DP V2 features a highly adaptable design. This system can easily transition from a modular to a compact setup, making it suitable for any space, regardless of how limited it might be.

 

Spot-free Water

This system is engineered to deliver spot-free water, crucial for applications like glass cleaning, yacht washing, or any other scenario where water spots are an issue.

 

Energy Efficient

Amid growing concerns about energy usage, the Aqua Matic DP V2 is built to be energy efficient, reducing your carbon footprint while providing clean, safe water.

 

Easy Maintenance

The Aqua Matic DP V2 is designed for hassle-free maintenance. Its modular design allows for quick and easy filter replacements, ensuring your water purifier always operates at peak performance.

Key Advantages for You

The Aqua Matic DP V2 has several features that benefit you. Below you find some of them listed:

  • Medium to high water production capacities available
  • Simple installation with fully automatic functionality
  • Energy-efficient with low power usage
  • Compact design suitable for confined engine room areas
  • Robust construction designed to endure harsh marine conditions and resist corrosion.

Inquiry the product and contact us now

Aquamatic DP 1 Parker Watermakers 1024 16X9
Aquamatic DP 2 Parker Watermakers 1024 16X9

Accessories for the Aqua Matic DP V2

The Aqua Matic DP V2 comes with an optional remote touch screen. This feature includes a clear viewable Sea Strainer equipped with a cleanable Monel Mesh Screen filter for superior corrosion resistance and effective removal of large particles.

Moreover, the following items are included when requested during order:

  • Charcoal Filter Assembly
  • Commercial Prefilter
  • Oil Water Separator
  • pH Neutralizer
  • Automatic Fresh Water Flush.

Need more information? Contact us now

Different Models - Same Excellence

We have made it easy for you to see the different models available of the Aqua Matic DP V2 from Paker Watermakers. They are listed below with the specifications.

Production/ 24 Hrs.
Model

Liters

A410M-1000GPD

3785

A410M-1300GPD

4921

A410M-1900GPD

7192

A410M-2600GPD

9842

Production/ Hr.
Model

Liters

A410M-1000GPD

158

A410M-1300GPD

205

A410M-1900GPD

300

A410M-2600GPD

410

Weight
Model

Kg

A410M-1000GPD

54.5

A410M-1300GPD

54.5

A410M-1900GPD

151.1

A410M-2600GPD

151.1

Recommended Spare Parts, Optional Accessories and Special Tools

Below we have gather all the recommended spare parts, optional accessories, and special tools, so it is easy for you to get an overview and have the part numbers easy accessible.

Exactly what you need? Contact us here

Spare Parts, Accessories and Special Tools

Builttoendure Parkerwatermakers 1024 16X9

Built to Endure: Vibration-Tested Watermakers Ensure Reliable Performance

Crafted for Quieter Operation:

Parker Water Purification watermakers are meticulously engineered with cutting-edge frames to maximize space utilization, diminish noise, and streamline maintenance procedures. With a remarkable reduction of 3db in sound levels, the Aqua Matic and Aqua Whisper DX systems offer unparalleled tranquility.

Vibration-Proof Design:

Our systems undergo rigorous manufacturing and testing processes to withstand continuous forces of up to 20 G's for over an hour of operation. This robust design ensures unwavering performance in any environment.

 

Do you have any questions? Contact us

More Water – Less Clutter!

Watermakers from Parker WP generate greater water output per square inch than any other system globally. With high-efficiency membranes, they boast a 17% increase in filtering surface area compared to conventional models, resulting in fewer membranes and installation space needed compared to competitors.

See the two examples here on the right.

Need our help? Contact us now.

Morewater Lessclutter Parkerwatermakers 1024 16X9

Your Benefits of the Watermakers Systems

Below we have gathered a few of the benefits of a Parker Water Purification Watermaker.

Less weight, lower fuel costs, higher speeds:

Sailing with a full water tank, or an additional 1,700 pounds, leads to squandered fuel, reduced speeds, and abbreviated voyages. With this watermaker, you can cruise swifter and longer while generating fresh water right onboard. Our systems not only save boaters time and money but also optimize yacht performance.

Cruise without limits or boundaries:

Having this watermaker onboard means you can bypass scheduling your boating ventures around marina stops. Cruise directly to your destination or venture to boundless distances without the necessity of replenishing fresh water supplies.

Fresh water wash downs:

Using Water Purification water for wash downs proves exceptionally efficient in safeguarding your yacht's exterior, potentially enhancing its overall value. Parker Water Purification water functions like a sponge, adeptly absorbing and rinsing away all undesirable sea salt and minerals, leaving surfaces spotlessly clean and free of water spots.

Convenient for every boating activity:

Regardless of whether you utilize it for drinking, showering, or cleaning your yacht, having a Water Purification watermaker offers endless opportunities to save money and enjoy more leisure time. With such advantages, how can any boater justify not owning this Water Purification watermaker?

Get more inforamtion - contact us now!
Aquamatic DP Parker Watermakers 1024 16X9
Aquamatic DP 1 Parker Watermakers 1024 16X9
Aquamatic DP 2 Parker Watermakers 1024 16X9
Rosystem Location 1 Parkerwatermakers 1024 16X9
Rosystem Location 2 Parkerwatermakers 1024 16X9
Aquamatic DP Parker Watermakers 1024 16X9
Aquamatic DP 1 Parker Watermakers 1024 16X9
Aquamatic DP 2 Parker Watermakers 1024 16X9
Rosystem Location 1 Parkerwatermakers 1024 16X9
Rosystem Location 2 Parkerwatermakers 1024 16X9

Installing your Reverse Osmosis System

The Reverse Osmosis(RO) system needs installation in a dry, sheltered area shielded from direct weather exposure. Adequate drainage should be ensured beneath the RO unit to facilitate water runoff during maintenance or repairs.

Rosystem Location 1 Parkerwatermakers 1024 16X9 Rosystem Location 2 Parkerwatermakers 1024 16X9

From Theory to Practice: Decoding Reverse Osmosis Mechanisms

The theory in short:

  • Osmosis: natural process involving semi-permeable membrane
  • Desalination: balances solution concentrations through membrane
  • Reverse Osmosis: high pressure reverses flow for purer solution
  • Feedwater concentration increases in Reverse Osmosis
  • Operating pressure: at least double membrane's osmotic pressure
  • Seawater composition: sodium chloride, calcium, sulfate
  • Total Dissolved Solids (TDS): averages 32,000 to 35,000 ppm.

Let’s take a deep dive into the theory.

Understanding Osmosis: Nature's Filtering Process

Osmosis, a natural phenomenon, occurs when a semi-permeable membrane separates a pure solution from a concentrated one (where a semi-permeable membrane selectively allows passage of substances). Each liquid carries an inherent potential closely tied to the nature and quantity of solids dissolved within it. This potential, termed osmotic pressure, rises with the relative concentration of a solution. Consequently, a concentrated solution exhibits a higher osmotic pressure compared to a pure solution.

Reverse Osmosis: Engineering Pure Water Solutions

In a desalination setup, the less concentrated solution balances the concentrations of both solutions by moving across the membrane. Once adequate pure solution migrates across the membrane to equalize the inherent potential difference, the flow of purer solution ceases.

However, if pressure on the concentrated solution exceeds the osmotic pressure, fluid flow reverses. This phenomenon, known as Reverse Osmosis, is achieved by artificially pressurizing the more concentrated solution using a high-pressure pump. In such a system, the concentrated solution (commonly called feedwater) becomes even more concentrated as pure water moves across the membrane to the permeate side.

Disregarding the impact of feedwater temperature and salinity, the operating pressure typically required to produce significant quantities of pure water is at least double the osmotic pressure of the membrane utilized.

Seawater Composition: Total Dissolved Solids Overview

Seawater encompasses various solids dissolved within it. The predominant component is typically ordinary table salt, sodium chloride. Additionally, other minerals found in solution often comprise diverse compounds of calcium and sulfate. The collective sum of these dissolved solids in a given water sample is termed Total Dissolved Solids or TDS. Seawater typically registers between 32,000 to 35,000 ppm (parts per million) TDS on average, although deviations of around 5000 ppm are commonplace across different regions globally. The primary objective of any desalination process is a notable reduction in the concentration of dissolved solids in water.

It's important to acknowledge that no system can entirely eliminate all dissolved solids from seawater. Instead, the system is engineered to reject approximately 99% of the TDS, allowing only 1% of the 35,000 ppm TDS in seawater to permeate into the product water. This results in water containing less than 500 ppm, the recommended TDS level for drinking water. A system configured in this manner is described as having a salt passage percentage of 1% or a salt rejection rate of 99%.

Membrane Magic: Inside the High-Tech World of Reverse Osmosis

The purified and strained raw water, now termed feedwater, enters the inlet of the high-pressure pump. This pump elevates the feedwater pressure to 56-65 BAR (800 - 950 psi), the standard pressure necessary for optimal system recovery. Subsequently, the pressurized feedwater is directed into the membrane pressure vessels, forming an array. This array comprises fiberglass pressure vessels, each housing RO membrane elements.

Within the membrane elements, reverse osmosis occurs as the pressurized feedwater flows. The feedwater is bifurcated into two streams: the high purity product stream (referred to as the product) and the increasingly concentrated reject stream (referred to as the reject).

Want to know more? Contact us now!

Maintaining RO Efficiency: Environmental Factors at Play

The table below demonstrates how alterations in temperature, salinity, and pressure impact both the quality and quantity of permeate generated by the RO system.

Should the salt concentration in the feedwater decrease, it's advisable to limit the increase in product water flow rate to no more than 20% above the rated flow. To maintain the rated flow in applications with brackish water or freshwater, adjustments to the Membrane Reject pressure may be necessary.

In scenarios where the feedwater salinity drops below the nominal level (e.g., near river mouths or in estuaries), the RO system can be fine-tuned to uphold a consistent permeate output. This adjustment can be achieved by manually controlling system pressure using the back-pressure regulator valve positioned in the system brine piping. To ensure prolonged pump life and minimal membrane fouling, Parker suggests not exceeding 9 psi, except in cases of extremely low temperature feed water.

BE AWARE that operating the unit at over 120% of its rated capacity in low salinity water can cause membrane damage.

Need more information? Contact us here.

General Watermakers FAQ

Accessory FAQ

Installation FAQ

Maintenance FAQ

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Parameter Specification

Technical Specifications for All Aqua Matic DP V2 Systems
Pump Type

1 or 2

Power Source

Sea Strainer with a cleanable Model Mesh Screen filter, Charcoal Filter Assembly, Commercial Prefilter, and Oil Water Separator

Salt Rejection

Automatic/ Semi Automatic

Feed Water Flow Rate

Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm(parts per million), are temperature compensated, and of a fail safe design.

Application

Leisure Marine

Performance

+-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Filter Area

Selected High Rejection/ High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element

Pressure Adjustment Control Type

AC

Salinity Range

99.2%, Average 99.4%

Chlorine Tolerange

Max. 122°F / 50°C, Min. 33°F / .5°C

Weight

4.5 gpm / 17 lpm (depending on system)

Height

0.1 ppm

Width

Feed Water: Maximum 35 psi / 2.41 bar / 2.46 KG/cm2

Length

Seawater nominal 820 psi / 5.5 bar / 57.66 KG/cm2

External Water Installation Connection Type

149-176 lbs/ 68-80 Kg

Electrical Specifications

Part Number: A410M-1000-1300 GPD
Phase

Single

Pump Motor

Booster

Voltage VAC

115/230

Hz

50/60

Normal Operating Amps

9.4/4.7//7.4/3.7

Part Number: A410M-1000-1300 GPD
Phase

Single

Pump Motor

HP

Voltage VAC

110/220/115/230

Hz

50/60

Normal Operating Amps

21/10.5//21.2/10.6

Part Number: A410M-1000-1300 GPD
Phase

Three

Pump Motor

Booster

Voltage VAC

208-230/460//190/380

Hz

60/50

Normal Operating Amps

2.5/2.4/1.2//2.2/1.1

Part Number: A410M-1000-1300 GPD
Phase

Three

Pump Motor

HP

Voltage VAC

 208-230/460//190/380

Hz

60/50

Normal Operating Amps

7/7.2/3.6//8.2/.41

Part Number: A410M-1900-2600 GPD
Phase

Single

Pump Motor

Booster

Voltage VAC

115/230

Hz

60/50

Normal Operating Amps

14.2/7.1//18.2/9.1

Part Number: A410M-1900-2600 GPD
Phase

Single

Pump Motor

HP

Voltage VAC

220/230

Hz

60/50

Normal Operating Amps

24/21.8

Part Number: A410M-1900-2600 GPD
Phase

Three

Pump Motor

Booster

Voltage VAC

220/380//230/460

Hz

60/50

Normal Operating Amps

5.4/2.7//5/2.5

Part Number: A410M-1900-2600 GPD
Phase

Three

Pump Motor

HP

Voltage VAC

190/380//230/460

Hz

60/50

Normal Operating Amps

15.6/7.8//13.4/6.7

Specifications & Manuals

  • Data Sheet - Aqua Matic DP V2 - Parker Watermakers
    English | pdf
  • Manual - Aqua Matic DP V2 - Parker Watermakers
    English | pdf
  • Brochure - Water Purification Product Catalog - Parker Watermakers
    English | pdf
  • Article - Watermakers FAQ - Parker Watermakers
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search