Logo
Sewage Water Test Kit Kvadrat

Insatech Sewage Effluent Test Kit

All vessels have to control their sewage discharge to comply with regulations and requirements including MEPC.2(VI), MEPC.159(55), and MEPC.227(64). Thus, the sewage effluent test kit should be part of your self-monitoring on board. Moreover, the content can be modified according to your needs.

The Sewage Effluent test kit gives you:

  • Easy sending like non-hazardous 
  • Cost-effective pass/ fail tests
  • Tests performed and executed by the crew
  • Easily documentation of all discharges
  • Non-hazardous.

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Cost-effective Sewage Effluent Test Kit 

With the cost-effective Sewage Water Test Kit, the crew on board can perform a pass/ fail test of the vessel’s sewage effluent. All tests are easy to perform and can be executed by the crew. Thereby, it is easily documented that all discharges comply with relevant regulations. Content can be modified according to your needs.

Moreover, the kits are non-hazardous, which makes it easy and cheap to ship to you!

MARPOL Annex IV contains a set of regulations regarding the discharge of sewage into the sea from ships, including regulations regarding the ships’ equipment and systems for the control of sewage discharge, the provision of port reception facilities for sewage, and requirements for survey and certification (ISPPC – International Sewage Pollution Prevention Certificate).

MARPOL Annex IV entered into force on the 27th of September 2003. All new ships with 400 gross tonnages and above; and new ships with less than 400 gross tonnages which are certified to carry more than 15 persons must comply with these regulations. 

From the 27th of September 2008, all existing ships with 400 gross tonnages and above; and existing ships less than 400 gross tonnages which are certified to carry more than 15 persons must comply with these regulations.

Regulations

The Ballast Water Test Kit is complying the following regulations and restrictions listed below.

Sewage 2 1024 16X9

MEPC.2(VI)

Coliforms - up to 250 CFU/100ml
Total Suspended Solids (TSS) (shore test) – up to 50 mg/l
Total Suspended Solids (TSS) (onboard test) – up to 100 mg/l
Biological Oxygen Demand (BOD) – up to 50 mg/l


As set out in Annex 22 Resolution MEPC. 227(64) adopted on the 5th October 2012, sewage treatment
plants installed prior to 1st January 2016 and on or after 1st January 2010, on ships other than passenger
ships operating in MARPOL Annex IV special areas and intending to discharge treated effluent into the sea,
should comply with resolution MPEC.159(55) adopted on 13th October 2006.

Need our help? Contact us now.

MEPC.159(55)

Coliforms – up to 100 CFU/100ml
Total Suspended Solids (TSS) – up to 35 mg/l
Biological Oxygen Demand (BOD) – up to 25 mg/l
Chemical Oxygen Demand (COD) – up to 125 mg/l
pH – between 6.0 – 8.5
Chlorine (Free) – up to 0.5 mg/l
As set out in Annex 22 Resolution MEPC. 227(64) adopted on the 5th October 2012, sewage treatment
plants installed on or after 1st January 2016, on ships other than passenger ships, in all areas; and
passenger ships outside MARPOL Annex IV special areas and intending to discharge treated effluent into
the sea, should comply with resolution MPEC.159(55) adopted on 13th October 2006.

Sewage 3 1024 16X9
Sewage 4 1024 16X9

MEPC.159(55)

Coliforms – up to 100 CFU/100ml
Total Suspended Solids (TSS) – up to 35 mg/l
Biological Oxygen Demand (BOD) – up to 25 mg/l
Chemical Oxygen Demand (COD) – up to 125 mg/l
pH – between 6.0 – 8.5
Chlorine (Free) – up to 0.5 mg/l
As set out in Annex 22 Resolution MEPC.227(64) adopted on the 5tH October 2012, for new passenger
ships when operating in a MARPOL Annex IV area and intending to discharge treated sewage effluent into
the sea on or after 1st January 2016, and existing passenger ships on or after 1st January 2018, should
comply should comply with resolution MPEC.159(55) adopted on 13th October 2006 and the following
additional effluent tests:

Do you have any questions? Contact us

MEPC.159(55)

Coliforms – up to 100 CFU/100ml
Total Suspended Solids (TSS) – up to 35 mg/l
Biological Oxygen Demand (BOD) – up to 25 mg/l
Chemical Oxygen Demand (COD) – up to 125 mg/l
pH – between 6.0 – 8.5
Chlorine (Free) – up to 0.5 mg/l
+

MEPC.227(64)

Total Nitrogen – up to 20 mg/l
Total Phosphorus – up to 1 mg/l

Sewage 5 1024 16X9

Contents

Sewage Effluent Test Kit #1 - Complies with MEPC.2(VI):

Sewage Treatment Plants Installed Prior to 1st January 2010

  • 1 x Marine Heavy Duty Case & Foam Set
  • 12 x Coliform Bacteria Test (0 – 2424 CFU/100ml)
  • 1 x Total Suspended Solids Test (5 – 500 mg/l) (Unlimited Tests)
  • 1 x Biological Oxygen Demand Test (7.5 – 255 mg/l) (Unlimited Tests)
  • 1 x Spirit Thermometer
  • 1 x Digital Incubator (110v/240v)
Sewage Effluent Test Kit #2 - Complies with MEPC.159(55):

Sewage Treatment Plants Installed After 01/01/2010 & Prior to 01/01/2016

Sewage Treatment Plants installed After 01/01/2016 on ships other than passenger ships & passenger ships operating outside MARPOL Annex IV Areas.

  • 1 x Marine Heavy Duty Case & Foam Set
  • 12 x Coliform Bacteria Test (0 – 2424 CFU/100ml)
  • 1 x Total Suspended Solids Test (5 – 500 mg/l) (Unlimited Tests)
  • 1 x Biological Oxygen Demand (BOD) Test (7.5 – 255 mg/l) (Unlimited Tests)
  • 1 x Chemical Oxygen Demand (COD) Test (0 – 300 mg/l) (100 Tests)
  • 1 x pH Test Strips (4 – 10 pH) (100 Tests)
  • 1 x Chlorine (Free) LR Comparator Test (0 – 1 mg/l) (100 Tests)
  • 1 x Chlorine (Free) Drop Test (0 – 30 mg/l) (100 Tests)
  • 1 x Spirit Thermometer
  • 1 x Digital Incubator (110v/240v)
Sewage Effluent Test Kit #3 - Complies with MEPC.159(55) & MEPC.227(64):

New Passenger Ships from the 01/01/2016 & Existing Passenger Ships from 01/01/2018 operating within MARPOL Annex IV areas.

  • 1 x Marine Heavy Duty Case & Foam Set
  • 12 x Coliform Bacteria Test (0 – 2424 CFU/100ml)
  • 1 x Total Suspended Solids Test (0 – 750 mg/l) (Unlimited Tests)
  • 1 x Biological Oxygen Demand (BOD) Test (7.5 – 255 mg/l) (Unlimited Tests)
  • 1 x Photometer
  • 1 x Chemical Oxygen Demand (COD) Test (0 – 1500 mg/l) (25 Tests)
  • 1 x pH Test (5 – 11 pH) (100 Tests)
  • 1 x Chlorine (Free) LR Test (0 – 1 mg/l) (50 Tests)
  • 1 x Chlorine (Free) Drop Test (0 – 30 mg/l) (100 Tests)
  • 1 x Total Nitrogen Test (0.5 – 25 mg/l) (25 Tests)
  • 1 x Total Phosphorus Test (0 – 2.6 mg/l) (25 Tests)
  • 1 x Spirit Thermometer
  • 1 x Digestor Unit (For COD, Total Nitrogen & Total Phosphorus Test)
  • 1 x Digital Incubator (110v/240v)
Sewage Effluent Test Kit #4 (BUDGET):
  • 1 x Marine Heavy Duty Case & Foam Insert
  • 10 x Coliform/TVC Bacteria Dip Slides (0 – 100,000 CFU/100ml)
  • 1 x Total Suspended Solids Test (5 – 500 mg/l) (Unlimited Tests)
  • 1 x Biological Oxygen Demand (BOD) Test (7.5 – 255 mg/l) (Unlimited Tests)
  • 1 x Chemical Oxygen Demand (COD) Test (0 – 300 mg/l) (100 Tests)
  • 1 x Chlorine (Free) LR Comparator Test (0 – 1 mg/l) (100 Tests)
  • 1 x Chlorine (Free) Drop Test (0 – 30 mg/l) (100 tests)
  • 1 x Universal PH Comparator Test (4 – 11 PH) (100 Tests)
  • 1 x Spirit Thermometer
Exactly what you need? Contact us here
Sewage Water Test Kit 169
Sewage 2 1024 16X9
Sewage 3 1024 16X9
Sewage 4 1024 16X9
Sewage 5 1024 16X9
Sewage 1 1024 16X9
Sewage Water Test Kit 169
Sewage 2 1024 16X9
Sewage 3 1024 16X9
Sewage 4 1024 16X9
Sewage 5 1024 16X9
Sewage 1 1024 16X9
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Product specifications and manuals

  • Sewage water test kit - Brochure
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search