INSATECH Cooltreat AL Test Kit 1 1

NALFLEET Cooltreat AL Test Kit

NALFLEET™ Cooltreat AL™ is an organic liquid corrosion inhibitor designed for closed cooling water systems, providing extended protection. It safeguards all typical materials used in engine cooling water systems, including aluminium. Unlike conventional coolants, NALFLEET™ Cooltreat AL™ does not contain components subject to rapid depletion i.e. Nitrite and Silicate. Utilizing aliphatic acid technology, NALFLEET™ Cooltreat AL™ is entirely organic and biodegradable.

Key Advantages for you:

  • Extended protection
  • Compatible with all common materials
  • Rapid depletion-free

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Dosing Method

NALFLEET™ Cooltreat AL™ should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured.

Sampling and Testing

The test kit provides the necessary equipment to carry out the control tests. Obtain a representative sample of the cooling water. Carry out the tests immediately and log the results. Use the dosage chart to adjust treatment to obtain the optimium level. It is important that testing is carried out at least once per week, to ensure levels of treatment are correct.

Doseage and Control

Initial dosage for an untreated system is 60 litres of NALFLEET™ Cooltreat AL™/ton of untreated distilled water (6%). This will provide sufficient protection of the system for a period of two to five years under normal conditions.

6% NALFLEET™ Cooltreat AL should also be dosed in all make up water added to the system to compensate for lost coolant. The engine manufacturers recommendations for water quality should always be complied with. Chloride levels should always be as low as possible. Most engine manufacturers recommend a maximum of 50ppm chlorides. It is recommended to use distilled water for the make-up. pH should be controlled between 7.0 and 9.0.

Need more information? Contact us here

Cooltreat Test Method

1. Rinse the shaker tube with clean water before use.
2. Fill the 1ml syringe to above the 1ml mark with Cooltreat Reagent. Ensure there are no air bubbles trapped. Set the plunger at the 1.0ml line.

NOTE: Check that there are no drops on the syringe tip. Then eject the 1ml into the shaker tube pushing the plunger fully down. Touch the tip of the syringe against the inside of the tube to collect the last drop.

3. Add 10 drops of Cooltreat Indicator from the dropper bottle. The solution will turn red.
4. Fill a disposable pipette with sample water. Add sample water a few drops at a time , swirling the tube with each addition. The colour will change to a cloudy purple, then a greyish colour. Add sample drop by drop at this point until a permanent green tint is produced. The sample may now be measured.
5. Read the % Cooltreat in the sample from the liquid level in the tube.
6. Record the result as % Cooltreat AL.

Interference: Note that presence of other types of corrosion inhibitors may cause incorrect results.

pH Test Method

1. Take a sample of water to be tested in a clean, suitable container.
2. Take a ph test strip and dip it in the sample for about 10 seconds.
3. Take the stripe out of the sample and compare its colour with that of the colour scale provided.
4. Read the pH value and note the date the test was carried out.
5. Record the result as pH.

Quantab Chloride Test Method

1. Remove a chloride test strip from the bottle and replace the cap immediately.
2. Insert the lower end of the titration strip into the sample. Do not allow the sample to reach the yellow completion band at the top of the strip (example 1).
3. Allow the sample water to completely saturate the wick of the titration strip. The reaction is complete when the yellow band turns dark (example 2).
4. Note where the tip of the white chloride peak falls on the numbered Quantab scale.
5. Refer to the table to convert Quantab units into chloride value.
6. Record the result as ppm Chloride.

Exactly what you need? Contact us here
Ordering Information Cooltreat AL Replacement Consumables
Part #

Description

WTS-K101789

Cooltreat AL Test Kit

WTS-P100923

Cooltreat AL Reagent Pack

WTS-P100924

Cooltreat AL Syringe & Pipette Pack

WTS-B101874

Cooltreat AL Shaker Tube

WTS-P101881

pH Test Strip 4-10 (100) 2 Pack

WTS-B101872

Hach Quantab Chloride Test Strip 30 - 600ppm (40)

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Product specifications and manuals

  • Instruction Manual - Cooltreat AL Test Kit - Insatech
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search