Standard DMP 331P Features

The DMP 331P pressure transmitter is precise and has the following features that benefits you:

  • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
  • Accuracy: 0.35 % (opt. 0.25 %) FSO
  • CIP / SIP cleaning up to 150 °C
  • Vacuum resistant
  • Hygienic version
  • Diaphragm with low surface roughness.

Furthermore, the several electrical connections complete the profile of the DMP 331P transmitter. Thus, the DMP 331P fulfills nearly all requirements in various industrial processes.

DMP331P Bdsensors 1024X16x9

Typical applications

The DMP 331P from BD Sensors is applicable in various settings including:

  • Maritime industry
  • Medical technology
  • Food and beverage.

Get more information here

Additional Available Features

If you have a specific need the DMP 331P pressure transmitter is available with optional features like:

  • IS-version, Ex ia = intrinsically safe for gases and dusts
  • SIL 2 according to IEC 61508 / IEC 61511
  • Cooling element for media temperatures up to 300 °C
  • Diaphragm in Hastelloy® or Tantalum.

Moreover, the modular construction concept of the transmitter allows a combination of various process connections with different filling fluids and a cooling element.

Does it match your need - contact us here

DMP331P 1 Bdsensors 1024 Square
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Model/ Type
Pressure

500: gauge 

501: absolute

Input [bar]

1000: 0.10 (Note 1)
1600:
0.16 (Note 1)
2500:
0.25 (Note 1)
4000: 0.40 
6000: 0.60
1001: 1.0
1601: 1.6
2501:
2.5
4001: 4.0
6001: 6.0
1002: 10
1602: 16
2502:
25
4002: 40
X102:
-1 ... 0
9999:
 customer

Output

1: 4 … 20 mA / 2-wire

2: 0 … 20 mA / 3-wire

3: 0 … 10 V / 3-wire

E: intrinsic safety 4 … 20 mA / 2-wire

1S: SIL2 4 … 20 mA / 2-wire

ES: SIL2 with intrinsic safety 4 … 20 mA / 2-wire

9: customer

Accuracy

standard for pN ≥ 0,4 bar
3:
0.35 % FSO

standard for pN ≥ 0,4 bar
5: 0.50% FSO

option for pN ≥ 0.4 bar
2: 
0.25% FSO

9: customer

Electrical connection

100: male and female plug ISO 4400

200: male plug Binder series 723 (5-pin)

TA0: cable outlet with PVC cable (IP67) (Note 2)

TR0: cable outlet, cable with ventilation tube (IP68) (Note 3)

M10: male plug M12x1 (4-pin) / metal

850: compact field housing stainless steel 1.4301 (304) (Note 4)

999: customer

Mechanical connection

Z00: G1/2" with flush welded diaphragm (DIN 3852) (Note 5)

Z30: G3/4" with flush welded diaphragm (DIN 3852)

Z31: G1" with flush welded diaphragm (DIN 3852)

Z57: G1" DIN 3852 with rad. o-ring G1" DIN 3852 with rad. o-ring (Note 6)

Z61: G1/2" DIN 3852 with rad. o-ring and flush diaphragm (Note 5)

K31: G 1" cone

C61: Clamp DN 25 / 1" (DIN 32676) / 3A

C62: Clamp DN 32 / 1 1/2" (DIN 32676) / 3A

C63: Clamp DN 50 / 2" (DIN 32676) / 3A

C69: Clamp 3/4" (DIN 32676) / 3A

M73: dairy pipe DN 25 (DIN 11851) (Note 4)

M75: dairy pipe DN 40 (DIN 11851) (Note 4)

M76: dairy pipe DN 50 (DIN 11851) (Note 4)

P41: Varivent® DN 40/50 / 3A

999: customer

Diaphragm

1: stainless steel 1.4435 (316L)

T: tantalum

H: Hastelloy® C-276 (2.4819)

9: customer

Seals

for clamp, dairy pipe, Varivent®
0: without

for inch thread - standard
1: 
FKM

for inch thread - option
7: 
FFKM

9: customer

Filling fluids

1: silicone oil

2: food compatible oil (FDA) / 3A

9: customer

Special version

000: standard

200: with cooling element up to 300°C / 3A

999: customer

Notes

1: absolute pressure possible from 0.4 bar
2: standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70°C), others on request
3: code TR0 = PVC cable, cable with ventilation tube available in different types and lengths
4: The cup nut has to be mounted by production of pressure transmitter with electrical connection field housing and mechanical connection dairy pipe. The cup nut has to be ordered as separate position.
5: possible only for pN ≥ 1 bar
6: possible only for pN ≤ 2 bar
Varivent® is a brand name of GEA Tuchenhagen GmbH, Hastelloy® is a brand name of Haynes International Inc

  • Data Sheet - DMP 331P - BD Sensors
    English | pdf
  • Owners Manual - DMP 331P - BD Sensors
    English | pdf
  • Owners Manual - IS version - DMP 331P - BD Sensors
    English | pdf
  • Certificate - Conformity Declaration - DMP 331P - BD Sensors
    English | pdf
  • Certificate - IS - DMP 331P - BD Sensors
    English | pdf
  • Certificate - IECEx - DMP 331P - BD Sensors
    English | pdf
  • Certificate - Functional safety data sheet - DMP 331P - BD Sensors
    English | pdf
  • Certificate - Functional safety data sheet is-version - DMP 331P - BD Sensors
    English | pdf
  • Certificate - 3A - DMP 331P - BD Sensors
    English | pdf
  • Certificate - EHEDG - DMP 331P - BD Sensors
    English | pdf
  • Article - Mounting instructions - DMP 331P - BD Sensors
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search