Logo
Vent Captor 3302.30 Xx.16 9 Stainless Steel

Vent Captor 3302.30/xx

The compact inline flow-meter vent-captor type 3302.30, is designed for industrial use and is well-suited for smaller diameters. The operating principle is based on the calorimetric principle, and its construction involves complete resin encapsulation, providing durability and making it resistant to shocks and vibrations

Key features

  • Rugged, shock and vibration proof
  • Linear current output 4 - 20 mA
  • Small pipe diameters
  • Ideally suited to small flow volume
  • Compact
  • ISO 9001:2015 certified

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Ideal for marine applications

The Vent-captor 3302.30 is an ideal choice for marine applications requiring precise monitoring of air and gas flow in small pipe diameters.

It´s an inline flow monitor for medium gas, utilizing the calorimetric measuring principle without mechanical components, makes it well-suited for marine environments.

The sensor accurately detects medium flow velocity and translates it into an electrical signal.

  • Sensor pipe sizes: 12 - 28mm
  • Max. pressure: 10 bar
Need more information? Contact us here
Vent Captor 3202.0X 16 9

Features

This inline flowmeter from Weber Sensors is ideal for small diameters and has several key features including:

  • Linear current output 4 - 20 mA
  • Temperature compensated
  • LED - output current range display
  • Rugged industrial version
  • Compact, no additional parts
  • Small pipe diameters
  • Ideally suited to small flow volume

Does it match your need - contact us now

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical data
Medium

gaseous (aggressive media on request)

Sensor data (all data related to medium air normal pressure)
Measuring range
  • 0 - 5 m/s
  • 0 - 10 m/s
  • 0 - 20 m/s
  • 0 - 30 m/s
Measuring range adjustment

continually adjustable from 20 % to 100 % of the special measuring range 2 potentiometers ( zero point, range )

Linearity deviation

< 5 % ( best fitting slope )

Repeatability tolerance

< 3%

Medium temperature

-20 °C to +70 °C

Ambient temperature

-20 °C to +70 °C 

Pressure

10 bar

Temperature drift

< 0.3 % per Kelvin

Mechanical data
Protection class

IP 65

Material sensor pipe

Stainless steel WN 1.4571 / AISI 316Ti

Dimensions in mm sensor pipe

diam. x wall thickness

  • 8x1
  • 12x1 
  • 18x1,5 
  • 22x1,5 
  • 28x1,5 
Torsion between pipe and housing

no torsion allowed

Material sensor probe

Ceramic, platinum with overglaze

Material housing

Makrolon®

Electrical connection

2 m moulded oilflex cable / 3 x 0.5 mm²

Electrical data
Operating voltage

24 VDC ±10%

Output current

4 – 20 mA

Current consumption

approx. 4.3W - 5,3 W ( max. flow )

Switching current

4 - 20 mA

Load

0 - 600 Ω

  • Data Sheet - Vent-captor 3302.30/xx - Weber Sensors