The flow-captor 422x.4xM from Weber Sensors is a compact and highly accurate flow switch featuring an analog display, all enclosed within a robust stainless steel housing. Moreover, the flow-captor enables the precise configuration of a flow set-point while concurrently displaying the flow rate, even under minimal flow conditions.

Key benefits for you:

  • Precise switching flow monitoring
  • Compact design
  • Highly accurate
  • BINDER coupling available
  • ISO 9001:2015

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Precision in Compact Stainless Steel

The Flow Captor model 422x.40/.41M is a precise, compact flow switch featuring an analog display, all enclosed within a robust stainless steel casing.

These devices operate based on the fundamental principles of calorimetry, which is elaborated further down.

The Flow Captor provides the capability to establish precise flow set-points and simultaneously displays the flow rate, even under conditions of minimal flow.

Flow Captor 422X.4Xms141 Weber 1024 16X9

Key Features

The flow-captor 422x.40/.41M from Weber Sensors has several key features including:

  • High-Precision Flow Monitor with Relay Output for Water or Oil-Based Media, Suitable for Pressures up to 100 bar
  • Available in the S141 version with BINDER coupling
  • Exceptional Accuracy, Even in Low Flow Scenarios
  • Individual Adjustments for "Range" and "Set-Point" Settings
  • Analog Display of Real-Time Flow Rate and the Set-Point Value
  • Includes an Analog Temperature Output
  • Compliant with ISO 9001:201 Certification Standards

Get more information here

Applicable for Two Different Media

The flow-captor type 422x.40/.41M is applicable for two different media:

  • 4220.4xM is applicable for water-based media
  • 4221.4xM is applicable for oil-based media.

 

Does it match your need - contact us here

Efficiency and Durability Unleashed:
Flow-Captor's Mechanical Simplicity with Calorimetry

The system operates on a fascinating and highly versatile measuring principle known as calorimetry. This calorimetric measuring principle is the cornerstone of the technology that underpins the flow-captor type 422x.4xM, and it offers a wide array of benefits and capabilities including:

  • Flexibility
  • No need for mechanical moving parts
  • Increased durability and reliability
  • Highly adaptable

At its core, calorimetry is a technique that measures changes in temperature to determine various properties of a substance or system. In the context of the flow-captor system, it means that the device can precisely detect and quantify temperature variations within the liquid media it is tasked with controlling.

What truly sets the calorimetric measuring principle apart is its incredible flexibility in adapting to different measurement ranges. This adaptability allows the flow-captor to cover a vast spectrum of quantities. Whether you're dealing with subtle temperature shifts or more significant fluctuations, the flow-captor can effectively adjust its measurement range to accommodate the specific requirements of your application. This capability ensures that it can handle a diverse range of scenarios within automation processes, industrial settings, and even marine applications where liquid media control is crucial.

Furthermore, the ability to utilize calorimetry means that the flow-captor operates without the need for mechanical moving parts. This is a significant advantage because it reduces wear and tear on the sensor, resulting in increased durability and reliability. In practical terms, this translates to fewer maintenance requirements and a longer operational lifespan for the device, ultimately saving time and resources.

In summary, the calorimetric measuring principle employed by the flow-captor type 422x.4xM is not only ingenious but also highly adaptable. It empowers the system to precisely monitor temperature changes within water or oil-based media, making it an invaluable tool in a wide range of industries and applications where precision and reliability are paramount.

Need more information? Contact us here.

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Medium

4220.40M/.41M: Water-based 

4221.40M/.41M: Oil-based

Sensor Data
Measuring range

4220.40M/.41M: 0 - 20 cm/s to 0 - 300 cm/s, cont. adjust (See note 1)

4221.40M/.41M: 0 - 30 cm/s to 0 - 300 cm/s, cont. adjust (See note 2)

Set-point range

ca. 15 % - 90 % of measuring range setting

Medium temperature

-20 °C to +80 °C

Ambient temperature

-20 °C to +70 °C

Pressure

max. 100 bar (1000 Kpa)

Response time

4220.40M/.41M: 2 - 10 sec., according to range setting 

4221.40M/.41M: 2 -15 sec., according to range setting

Linearity deviation

4220.40M/.41M: < 5 % (see note 1)

4221.40M/.41M: < 5 % (see note 2)

Repeatability

< 2 %

Hysteresis

ca. 10 %

Mechanical data
Protection class

IP 67

Material housing

stainless steel WN 1.4305 / AISI 303 (M)

Material of sensor head

stainl. steel WN 1.4305 / AISI 303 alt. WN 1.4571 / AISI 313Ti (A ), other materials on request

Thread

G ½ “ BSP, alt. ½ “ 14 - NPT

Electrical connection

2 m oilflex cable, 7 x 0,5 mm²

Electrical data
Operating voltage

18 - 30 VDC

Switching current / Contact load

 ≤ 5 A, 120 VAC / ≤ 3A, 250 VAC / 5A, 150W at VDC

Electrical output, flow

Relay with potential contact

Initial operation

approx 10 sec. after connection of power

Flow < set-point

4220.40M/.41M: .40

4221.40M/.41M: .41

LED, green

4220.40M/.41M: off

4221.40M/.41M: off

Output relay

4220.40M/.41M: activated

4221.40M/.41M: not activated

Temperature output

-10 °C to +80 °C 4 – 20 mA

Notes

1) data relate to water
2) calibrated with insulation oil type "Shell Diala S4 ZX-I"

  • Data Sheet - Flow-captor 422x.4xM - Weber Sensors
    English | pdf
  • Instruction Manual - Flow-captor 422x.4xM - Weber Sensors
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search