Flow Captor 4130.1X Intro

Flow Captor 4130.1x and 4131.1x

The flow-captor 413x.1x from Weber Sensors is a flow switch for water and oil based media, with fixed, not changeable measuring range. Its ideally suited for use in automation processes or other industrial applications
where liquid media must be monitored.

Key benefits for you:

  • Precise switching flow monitoring
  • Different sensor head lenghts, materials and BSP or NPT
  • Highly accurate
  • Robust industrial design
  • ISO 9001:2015

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

 Flow-captor 413x.1x is based on 412x.1x

This flow switch is based on the Flow-captor 4121.1x. The different is that this type comes with a fixed, and not changeable measuring range. 

Set-point and fixed range of:

  • 0.4 m/s
  • 1.0 m/s
  • 2.0 m/s

Sensor Head Features

The sensor head is a single piece made of electropolished stainless steel, ensuring no sensor element intrudes into the medium - Available in 5 different lengths.

Easy installation can be achieved using a T-piece or welded fitting. For aggressive media, alternative materials can be provided upon request.

Housing Details

The housing is constructed from glass fiber reinforced PBTP (Ultradur®). The electronics inside are completely encapsulated in epoxy resin for added durability.

Sensor Head Captor 4130.1X

The Flow-captor 413x.1x provides flexibility through different sensor head choices

  • Regular ½" BSP thread
  • Extended sensor probes with ½" BSP thread
  • NPT thread can be selected if needed
  • For smaller pipes, there's a ¼" BSP thread option
  • A cooling variant (flow-captor 413x.1x S101) for medium temperatures up to 130 °C.

Applicable for Two Different Media

The flow-captor type 413x.1x is applicable for two different media:

  • 4130.1x is applicable for water-based media
  • 4131.1x is applicable for oil-based media

 

Does it match your need - contact us here

Flow Captor 4130.1X 16 9

Efficiency and Durability Unleashed:
Flow-Captor's Mechanical Simplicity with Calorimetry

The system operates on a fascinating and highly versatile measuring principle known as calorimetry. This calorimetric measuring principle is the cornerstone of the technology that underpins the flow-captor type 413x.1x, and it offers a wide array of benefits and capabilities including:

  • Flexibility
  • No need for mechanical moving parts
  • Increased durability and reliability
  • Highly adaptable

Flow-Captor's reliance on the adaptable calorimetry principle ensures precise temperature monitoring in liquid media. Its versatile range of measurement options makes it indispensable across industries. The absence of moving parts boosts longevity and reliability, reducing maintenance demands for users.

Need more information? Contact us here.
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Medium

4130.1x: Water-based 

4131.1x: Oil-based

Sensor Data
Measuring range

Must be specified when ordering, choose between:

  • 0 - 0.4 m/s
  • 1.0 m/s 
  • 2.0 m/s
Set-point range

ca. 15 % - 90 % of measuring range setting

Medium temperature

-20 °C to +80 °C

Ambient temperature

-20 °C to +70 °C

Pressure

max. 100 bar (1000 Kpa)

Response time

4130.1x: 2 - 10 sec., according to range setting 

4131.1x: 2 -15 sec., according to range setting

Linearity deviation

4130.1x: < 5 % (see note 1)

4131.1x: < 5 % (see note 2)

Repeatability

< 2 %

Hysteresis

ca. 10 %

Mechanical data
Protection class

IP 65

Material housing

PBTP, glass fibre reinforced (Ultradur ®) 

Material of sensor head

Stainless steel AISI 303 (other material on request)

Sensor head sizes
  • flow-captor 413x.1xA / ¼" BSP, Length 20 mm, ¼” BSP
  • flow-captor 413x.1x / ½" BSP, Length 30 mm, ½" BSP
  • flow-captor 413x.1xA / ½" BSP S110/45, Length 45 mm, ½" BSP
  • flow-captor 413x.1xA / ½" BSP S110/67, Length 67 mm, ½" BSP
  • flow-captor 413x.1xA / ½" BSP S110/90, Length 90 mm, ½" BSP
Electrical connection

Integrated plug connection with PG9 fitting, 2 m oilflex cable 3 x 0,5 mm²

Electrical data
Operating voltage

18 - 30 VDC

Current consumption

max. 150 mA (pulsed)

Power consumption

approx. 1 W

Switching current

≤ 400 mA

Circuit protection

reverse polarity, short circuit and overload

Voltage drop

< 2.5 V at max. load

Initial operation

approx. 10 sec. after connection of power

Notes

1) data relate to water
2) calibrated with insulation oil type "Shell Diala S4 ZX-I"

  • Data Sheet - Flow-captor 413x.1x - Weber Sensors
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search