OMD-24 Series Bilge Alarm Units

The OMD-24 Series Bilge Alarm Units are specifically designed for use with 15 ppm oil-water separator units. Their specification and performance exceed the International Maritime Organization (IMO) standards for 15 ppm Bilge Alarms as per Resolution MEPC.107 (49).

The Bilge Alarm Units features:

  • Adjustable set points
  • Malfunction indicators
  • Optional data logging outputs.

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

OMD-24 Bilge Alarm: 15ppm Oil-Water Separators

The OMD-24 Bilge Alarm Unit is engineered for integration with 15 ppm oil-water separator units, surpassing the International Maritime Organization’s standards for 15ppm Bilge Alarms as per Resolution MEPC. 107 (49).

It comes with two factory-set alarms at 15 ppm, with adjustable set points (10 ppm or 5 ppm) configurable on-site via the front panel buttons. If the alarm threshold is exceeded, indicators on the front panel activate, and corresponding relays are triggered.

In the event of a malfunction, the System LED on the front panel shifts from blinking green to solid red. For data logging, the unit requires a status input from the separator.

Additionally, an optional 0(4) - 20 mA output (equivalent to 0 - 30 ppm) is available for connecting to a recorder or external meter.

 

Adjustable Alarms

Each unit comes with two factory-set alarms at 15 ppm. However, set points from 1 ppm to 15 ppm can be adjusted on-site at any time using the front panel buttons. If an alarm set point is exceeded, the alarms are visible on the front panel and the appropriate relays are triggered.

Inquiry the product and contact us now

ODM 24 Series 1 Deckma 1024 16X9
ODM 24 Series Deckma 1024 16X9

Malfunction Indicators and Data Logging

In case of a malfunction, the "SYS LED" on the front panel changes from blinking green to solid red. For data logging, the unit requires a status input from the separator. A 0(4) - 20 mA signal output (equivalent to 0 - 30 ppm) is available for connecting to a recorder or external meter.

Need more information? Contact us now

Recommended Spare Parts, Optional Accessories and Special Tools

Below we have gather all the recommended spare parts, optional accessories, and special tools, so it is easy for you to get an overview and have the part numbers easy accessible.

Exactly what you need? Contact us here

Spare parts, Recommended On board Spares, and Optional Equipment

ODM 24 Series 3 Deckma 1024 16X9

Additional Features

By request, the OMD-24 Series can be configured with a 5 ppm alarm set point. Instrument versions with a Measuring Cell Cleaning Unit or an Automatic Cell Cleaning Device are also available.

The OMD-24 Series generally includes a Computer Unit, a Measuring Cell, and additional equipment (such as Valve Assembly, Electrical Valve, Flow Control, and Automatic Cell Cleaning Device).

 

Do you have any questions? Contact us

Components and Assembly

The Computer Unit houses the display PCB, data logger, and terminals for external connections.

The Measuring Cell is constructed from anodized all-aluminum with stainless steel inlet and outlet blocks, containing optics and electronics connected to the Computer Unit via a data cable.

The Measuring Cell, which should be mounted vertically, is attached to a valve support that also holds the valve assembly. Sample and clean water usage are controlled by an electric Switchover Valve, connected to the measuring cell by a push-in connector.

Need our help? Contact us now.

ODM 24 Series 2 Deckma 1024 16X9

Installation Guidelines for the ODM-24 Series

The OMD-24 units can be wall-mounted or installed on a bulkhead. If space is limited, the Computer Unit can be separated from the Measuring Cell with an optional connection cable allowing up to 5 meters of distance. The OMD-24 Series should be located as close to the oily water separator as possible to minimize response delays. According to MEPC.107(49), the overall response time, including the 15 ppm Bilge Alarm’s response time of less than 5 seconds, and the operation of the Automatic Stopping Device, should not exceed 20 seconds.

Mounting and Connections

Mount the OMD-24 Series instruments using M6 or M8 screws on a rigid vertical surface or frame, with the display panel positioned conveniently. Ensure sufficient space for service and maintenance. When connecting pipes, avoid torsion and potential damage to the instrument. For separator discharge pipes up to 75 mm OD, a standard "T"-type junction is satisfactory for the tapping point. For larger pipes, a sample probe should protrude into the discharge piping by approximately 25% of the pipe's ID. Electrical connections are made through metric cable gland openings prepared underneath the instrument.

Electrical Installation

Connect the units to the mains supply via a suitable rated and approved fused isolator unless such fusing/isolation is provided by associated equipment. The isolator should be close, easily accessible, and clearly marked. Ensure the terminal cover is closed completely after installation to prevent water and humidity from entering the instrument, which could cause corrosion and malfunction.

Get more inforamtion - contact us now!
ODM 24 Series Deckma 1024 16X9
ODM 24 Series 1 Deckma 1024 16X9
ODM 24 Series 2 Deckma 1024 16X9
ODM 24 Series 3 Deckma 1024 16X9
ODM 24 Series Deckma 1024 16X9
ODM 24 Series 1 Deckma 1024 16X9
ODM 24 Series 2 Deckma 1024 16X9
ODM 24 Series 3 Deckma 1024 16X9
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Range:

0 – 30 ppm, Trend indication 50 ppm

Accuracy:

According IMO MEPC. 107(49)

Linearity:
Display:

Yellow Graphic Display

Power Supply:

24 V AC or DC +/- 10%

Consumption:

< 5 VA

Alarm Points 1 + 2:

Adjustable between 1 – 15 ppm*
(Works adjustment 15 ppm)

*By request the alarm set point can be set to 5 ppm max.

Alarm 1 Operating Delay: (for annunciation purpose)

Adjustable between 1 – 540 sec.
(Works adjustment 2 sec.)

Alarm 2 Operating Delay: (for control purposes)

Adjustable between 1 – 10 sec.
(Works adjustment 10 sec.)

Alarm Indication: (Alarm 1, 2, System Fault)

Red LEDs

Alarm Contact Rating: (Alarm 1, 2, System Fault)

Potential free 1 pole change over contacts,
3 A / 240 V.

Output Signal:

0 – 20 mA or 4 – 20 mA selectable,
ext. Load < 150 

Sample/ Fresh Water pressure:

0 – 10 bar recommended range of installation

Sample Flow:

Approx. 0.1 – 3 l/min

Sample Water Temperature:

+1 to +65 °C

Ambient Temperature:

+1 to +55 °C

Roll:

Up to 45°

Size:

Computer Unit: 185 mm W x 210 mm H x 65 mm D

Measuring Cell Assembly: 140 mm W x 160 mm H x 65 mm D

Distance Computer Unit to Measuring Cell:

Up to 0.5 m

Weight: (with Measuring Cell)

2.5 kg

Degree of Protection:

IP 65

Pipe connections:

R ¼" Female

Specifications & Manuals

  • Manual - ODM-24 Series - Deckma