Logo
Ferrous Wear Meter

ATR Analyser

The ATR Analyser from Parker is a reagentless test analyser, providing safe and cost-effective analysis for the marine industry. It offers multi-parameter testing for water content, base number, acid number, anti-wear additive, soot loading, viscosity, and FAME content in oil and fuel. 

With the ATR Analyser, you can:

  • Detects contamination
  • Ensure reliable trending analysis
  • Conduct multi-parameter testing

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Accurate and reliable oil and fuel testing instrument

Condition monitoring of lubricants and fuels is a top priority for engineers across various industries, including the marine industry. Contaminated or degraded lubricants and fuels can result in a myriad of issues, from inefficiencies and costly downtime to expensive repairs and permanent damage.

Although chemical testing remains a common method for analyzing lubricants and fuels, it involves transporting, handling, and disposing of hazardous chemicals. The ATR Analyser from Parker Kittiwake addresses these concerns by eliminating the need for chemical testing.

Main advantages and benefits with the ATR analyser: 

  • Faster testing - all results delivered in <3 minutes
  • Easy to use - no specialist training required
  • Low maintenance - simply wipe clean after use
  • Reagentless - no supply logistics or costs
  • Option to upgrade - for analysis of additional fluid types
ATR Analyser

One product, test on seven parameters

Easily usable, the Parker Kittiwake ATR Analyser facilitates multi-parameter testing for various types of oil and fuel.

  • Mineral oil - Water content: 0 – 20,000 ppm by mass
  • Mineral oil - Base number (BN): 0 – 150 mg KOH / g
  • Mineral oil - Acid number (AN): 0 – 10 mg KOH / g
  • Mineral oil - Anti-wear additive: 2 0 – 20 AU per 0.1mm
  • Mineral oil - Soot loading: 0 – 5.0 % by mass
  • Mineral oil - Viscosity: 5 - 450 cSt3
  • Diesel fuel - FAME content: 0.1 – 99.9 % by mass

Exactly what you need? Contact us here

Ordering Information
Part Number

Description

FG-K4-120-KW-A-H

ATR Analyser

ACCK05004

ATR Consumable pack including:

  • Pipette 3ml (100)
  • Alcohol wipes (100)

Using the Parker ATR Analyser: A step-by-step guide

In any conditions, the ATR Analyser provides a simple testing method that anyone can operate.

Steps:

  1. Power On: Turn on the device and wait for the home screen to appear
  2. Select Oil/Fuel Type: Choose the type of oil or fuel being tested
  3. Follow Instructions: Follow the on-screen instructions provided
  4. Sample Placement: Place the oil sample onto the ATR crystal using the provided pipette
  5. Start Test: Select 'start test' to initiate the analysis
  6. View Results: The measured values are displayed on-screen and stored in memory for future reference

Bringing lab efficiency to the field

The ATR Analyser simplifies field testing with its self-performing internal checks, requiring no recalibration and minimal maintenance. Key benefits include:

  • Quick Testing and Real-Time Results: Detect potential issues within minutes, preventing significant damage
  • User-Friendly Design: The ATR Analyser employs a straightforward method accessible to anyone, eliminating the need for extensive training
  • Multi-Parameter Analysis: Save time and money by consolidating tests, avoiding hazardous and time-consuming chemical procedures
  • Easy Maintenance: Simply clean the ATR crystal with supplied wipes after each use
  • Reliable Trends: Obtain results consistent with established laboratory standards
  • Minimal Equipment: Streamline oil and fuel analysis, reducing onboard equipment to just the ATR Analyser
  • Customized Analysis: Upgrade the ATR Analyser for analyzing various fluid types, tailoring to specific needs
Inquiry the product and contact us now
ATR Analyser Suitcase
ATR Analyser From Top
ATR Analyser From Behind
ATR Analyser Features With Text
ATR Analyser
ATR Analyser Suitcase
ATR Analyser From Top
ATR Analyser From Behind
ATR Analyser Features With Text
ATR Analyser
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Measurement Range
  • Mineral oil - Water content: 0 – 20,000 ppm by mass
  • Mineral oil - Base number (BN): 0 – 150 mg KOH / g
  • Mineral oil - Acid number (AN): 0 – 10 mg KOH / g
  • Mineral oil - Anti-wear additive: 2 0 – 20 AU per 0.1mm
  • Mineral oil - Soot loading: 0 – 5.0 % by mass
  • Mineral oil - Viscosity: 5 - 450 cSt3
  • Diesel fuel - FAME content: 0.1 – 99.9 % by mass
Rated input voltage

12 V d.c. (regulated power supply)

Rated input current

0.7 A

Operating temperature

10°C to 40°C

IP rating

IP 22

Instrument weight

1.6 kg

Test time

100 seconds

Unit dimensions
  • 246mm wide
  • 276mm deep
  • 81mm high

 

Specifications & Manuals

  • ART Analyser: Oil and fuel condition monitoring instrument - Parker Kittiwake
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search