Mechanical data | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Construction | stainless steel housing integrated mounting plate |
||||||||||||||||||
Repeatability | better than 1 mm within linear range |
||||||||||||||||||
Temperature drift | ≤ 0,5 mm within linear range |
||||||||||||||||||
Ambient temp. range | -20 °C to +70 °C |
||||||||||||||||||
Vibration and shock | in accordance with DIN 57 4 11 |
||||||||||||||||||
Zero point adjustment | potentiometer |
||||||||||||||||||
Sensitivity adjustment | potentiometer |
||||||||||||||||||
Protection standard | IP 65 |
||||||||||||||||||
Housing | stainless steel housings, integrated mounting plate, encapsulated epoxy resin |
||||||||||||||||||
Mounting plate | 220 x 220 mm (standard) |
||||||||||||||||||
Connection | 2 x 2 m silicone armoured cable each 3 x 0 .75 mm2 |
||||||||||||||||||
Measuring distance at full coverage | max. 140 mm, see graph in datasheet |
||||||||||||||||||
Mass | 14 kg |
||||||||||||||||||
Linear range | 35 .... 65 mm±1 mm |
||||||||||||||||||
Power consumption | 10 W |
||||||||||||||||||
Supply voltage | Supply voltage must be specified
|
||||||||||||||||||
Output load |
|
||||||||||||||||||
Electrical output |
|