Technical Specifications | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Medium | oil-based solutions |
Sensor data type 4205 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing | stainless steel, WN 1.4305 |
||||||||||||||||||
Union nut | M36x2 |
||||||||||||||||||
Sensor connection | 55 cm shielded 5 x 0.5 mm2 |
||||||||||||||||||
Connector | 5 - pin male plug (Cannon) |
||||||||||||||||||
Temperature of medium | -20 °C to +100 °C |
||||||||||||||||||
Flow measuring range | 0 - 400 cm/s (related to oil, type Shell Diala S4 ZX-I) |
Electrical data (electronic unit) type 4053.31 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Protection class | IP 65 |
||||||||||||||||||
Housing | aluminium, surface protection: SurTec 650 chromitAL |
||||||||||||||||||
Supply voltage | 24 VDC ± 10% |
||||||||||||||||||
Ambient temperature | -20 °C to +70 °C |
||||||||||||||||||
Connection | 5 - pin female socket (Cannon) |
||||||||||||||||||
Output / supply connection | 4 - pin male socket (Cannon) |
||||||||||||||||||
Output / supply connector | cable, 2 m length (different cable length on request ), with one female plug (Cannon) |
Output | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
temperature | Measuring range (See note 1): 20 °C to +100 °C (See note 2) Analog output: 0 - 10 V Curve: linear |
||||||||||||||||||
Flow | Measuring range (See note 1): 0 to 400 cm/s* (See note 2) Analog output: 0 - 10 V Curve: no linearization |
||||||||||||||||||
Notes | 1) fixed, no range adjustment 2) related to oil, Shell Diala S4 ZX-I |