Technical Specifications | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Medium | 4120.5xM: Water-based 4121.5xM: Oil-based |
Sensor Data | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measuring range | 4120.5xM: 0 - 20 cm/s to 0 - 300 cm/s, cont. adjust (See note 1) 4121.5xM: 0 - 30 cm/s to 0 - 300 cm/s, cont. adjust (See note 2) |
||||||||||||||||||
Set-point range | ca. 15 % - 90 % of measuring range setting |
||||||||||||||||||
Medium temperature | -20 °C to +80 °C |
||||||||||||||||||
Ambient temperature | -20 °C to +70 °C |
||||||||||||||||||
Pressure | max. 100 bar (1000 Kpa) |
||||||||||||||||||
Response time | 4120.5xM: 2 - 10 sec., according to range setting 4121.5xM: 2 -15 sec., according to range setting |
||||||||||||||||||
Linearity deviation | 4120.5xM: < 5 % (see note 1) 4121.5xM: < 5 % (see note 2)
|
||||||||||||||||||
Repeatability | < 2 % |
||||||||||||||||||
Hysteresis | ca. 10 % |
Mechanical data | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Protection class | IP 67 |
||||||||||||||||||
Material housing | Stainless steel AISI 303 or equivalent |
||||||||||||||||||
Material of sensor probe | Stainless steel AISI 303 or equivalent (other material on request) |
||||||||||||||||||
Thread | G ½ “ BSP, alt. ½ “ 14 - NPT |
||||||||||||||||||
Electrical connection | 2 m oilflex cable, 4 x 0.75 mm²
|
Electrical data | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Operating voltage | 90 - 250 VAC/DC |
||||||||||||||||||
Switching current / Contact load | Max. 100 mA at 90 - 250 VAC/DC |
||||||||||||||||||
Initial operation | approx 10 sec. after connection of power |
||||||||||||||||||
Electrical output | Solid state relay (SSR) |
||||||||||||||||||
Flow < set - point | 412x.52M: Led on 412x.53M: Led off |
||||||||||||||||||
Notes | 1) data relate to water |