Logo
Specifications
Measurement
  • Oil Types:  HFO, Diesel, and Mixture C (IMO defined)
  • Clean water calibration: +/- 2ppm of factory set values
  • Oil range: 0 - 40 ppm
  • Accuracy oil + solids:  + / - 5 ppm up to 30 ppm
  • Solids discrimination: 100 ppm Iron Oxide in 10 ppm Diesel
  • Response time: < 5 sec (oil reading)
Alarms
  • Oil alarm 1 setpoint: 1 - 15 ppm user adjustable
  • Oil alarm 2 setpoint: 1 -15  ppm user adjustable
  • Oil alarm 1 delay: 0 - 5 seconds user adjustable
  • Oil alarm 2 delay: 0 - 600 seconds user adjustable
Input / Output
  • Analogue output: Loop powered 4-20mA / 0 - 20mA 24V
  • Switch inputs: 2 x switch inputs for separator & flow status
Data Storage and Retrieval
  • Calibration data storage: Stored in cell
  • IMO required data: Stored in Control enclosure
  • IMO required data retrieval: Via LCD displays, RS 232 comms link, or USB
Systems and Supply
  • Supply voltage: 115 or 230V AC, 50 - 60Hz (24V AC & 12V DC available)
  • Supply voltage Consumption: <50 VA incl. solenoid valve
  • Supply voltage tolerance: +/- 15%
  • Projected life:  > 50.000 hrs
  • Protection class: IP 65
  • Approvals: MEPC 107(49) - DNV-GL, USCG, CCS, Class NK, Russian Register, Transport Canada
  • Weight: 3,2 Kg / 7,05lb
To top