Measurement |
- Oil Types: HFO, Diesel, and Mixture C (IMO defined)
- Clean water calibration: +/- 2ppm of factory set values
- Oil range: 0 - 40 ppm
- Accuracy oil + solids: + / - 5 ppm up to 30 ppm
- Solids discrimination: 100 ppm Iron Oxide in 10 ppm Diesel
- Response time: < 5 sec (oil reading)
|
Alarms |
- Oil alarm 1 setpoint: 1 - 15 ppm user adjustable
- Oil alarm 2 setpoint: 1 -15 ppm user adjustable
- Oil alarm 1 delay: 0 - 5 seconds user adjustable
- Oil alarm 2 delay: 0 - 600 seconds user adjustable
|
Input / Output |
- Analogue output: Loop powered 4-20mA / 0 - 20mA 24V
- Switch inputs: 2 x switch inputs for separator & flow status
|
Data Storage and Retrieval |
- Calibration data storage: Stored in cell
- IMO required data: Stored in Control enclosure
- IMO required data retrieval: Via LCD displays, RS 232 comms link, or USB
|
Systems and Supply |
- Supply voltage: 115 or 230V AC, 50 - 60Hz (24V AC & 12V DC available)
- Supply voltage Consumption: <50 VA incl. solenoid valve
- Supply voltage tolerance: +/- 15%
- Projected life: > 50.000 hrs
- Protection class: IP 65
- Approvals: MEPC 107(49) - DNV-GL, USCG, CCS, Class NK, Russian Register, Transport Canada
- Weight: 3,2 Kg / 7,05lb
|