Logo
Parker iCountPD

MTD Range: 4+, 6+, 14+, 21+, 38+ and 70+ microns

A particle sensor for permanent installation. The IcountPD Inline Particle Detector is an innovative product, and the latest technology in solid particle detections and contamination control, with dynamic design, for use in all applications.

Key Features

  • Particle detector for mineral oil
  • Independent monitoring & Continuous performance

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

3 versions of iCountPD

  • Standard iCountPD is designed for test stand, flushing skids, filter carts and other industrial applications.
  • iCountPDR is design for mobile equipment or any outside use other than hazardous environment.
  • iCountPDZ is suited for application that require a ATEX Zone II safty such as off-shore platforms or any other hazardous environment. For Zone I applications, the standard iCountPD can be used within a NEMA7 enclosure.

The Parker iCountPD is a highly compact, Inline laser detection particle size monitor that enables continuous monitoring of contamination levels in hydraulic and fluid circuits. It is available in three configurations to meet unique requirements.

 

 

Insatech Parker Icountpd

Features and benefits

  • Warning LED or digital display indicators.
  • Fully integrated PC/PLC integration technology, such as: RS232 and 0-5Volt, 4...20mA, CAN(J1939)
  • Monitoring the system contamination independently and continuously.
  • Moisture % RH indicator (optional).
  • Hydraulic, phosphate ester & fuel fluid compatible construction.
  • Self diagnostic software.
  • Inline and can be used while machinery is in operation, which ensures system uptime.

Typical Applications

Mobile Equipment
  • Earth Moving Machinery, Harvesting Forestry, Agriculture
Industrial Equipment
  • Production Plants, Fluid Transfers, Pulp & Paper, Refineries

Power Generation
  • Wind Turbines, Gearboxes, Lubrication
Systems Maintenance
  • Test Rigs, Flushing Stands

Insatech Parker Icount PD Z2
Insatech Parker Icount PD DIG
Insatech Parker Icount PD Z2
Insatech Parker Icount PDR
Insatech Parker Icountpd
Insatech Parker Icount PD DIG
Insatech Parker Icount PD Z2
Insatech Parker Icount PDR
Insatech Parker Icountpd
Ordering Information
Part Number

Display, Communication, Moisture

IPD12222130

LED, RS232 / 4 - 20 mA, NO

IPD12222230

LED, RS232 / 4 - 20 mA, YES

IPD12223130

LED, RS232 / 0 - 5 V, NO

IPD12223230

LED, RS232 / 0 - 5 V, YES

IPD12322130

Digital, RS232 / 4 - 20 mA, NO

IPD12322230

Digital, RS232 / 4 - 20 mA, YES

IPD12323130

Digital, RS232 / 0 - 5 V, NO

IPD12323230

Digital, RS232 / 0 - 5 V , YES

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Measurement Period

5-180 seconds

Principle of Operation

Laser diode optical detection of actual particulates

Reproducibility / Repeatability

Better than 1 ISO code

Power Requirement

Regulated 9 to 40 Vdc

Current Rating

Typically 120 mA

Required Flow Rate

40 to 140 ml/min (optimum flow = 60 ml/min)

Viscosity Range

1 - 500 cSt

Ambient Storage Temperature

-20°C to +40°C (-4°F to +104°F)

Environment Operating Temperature

+5°C to +60°C (+41°F to +140°F)

Fluid Operating Temperature

+5°C to +80°C (+41°F to +176°F)

Working Pressure

2 to 420 bar (30 - 6000 PSI)

Operating Humidity Range

5% RH to 100% RH

Dimensions

182 mm x 155 mm x 86 mm

Weight

1.3kg

Specifications & Manuals

  • Brochure - iCountPD Online Particle Detector - Parker
    English | pdf
  • Manual - iCount PD - Parker
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search