Technical Specifications FRG00035 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Output interface | I: I2C R / N (Note 1): RS232 C: Relay (2x) A: Analog (2x) AC (Note 2): Analog (2x) / Relay (3x) |
||||||||||||||||||
Output information | I: Humidity, Temp., PAV, MAV R / N (Note 1): Humidity, Temp., PAV, MAV C: PAV, MAV A: Humidity, Temp. AC (Note 2): Humidity, Temp., PAV, MAV, STATUS |
||||||||||||||||||
Output characteristics | I: Serial R / N (Note 1): Serial C: Analog 4 ... 20mA / load max. 500 Ω. Relay max. 500mA A: Analog 4 ... 20mA / load max. 500 Ω. Relay max. 500mA AC (Note 2): Analog 4 ... 20mA / load max. 500 Ω. Relay max. 500mA |
||||||||||||||||||
Accuracy of humidity measurement | ±3% |
||||||||||||||||||
Pressure resistance against medium | 10 bar |
||||||||||||||||||
Protection degree | IP67 |
||||||||||||||||||
Power supply | I: 5 VDC ± 5% R / N (Note 1): 18 ... 32 VDC, max. perm. ripple ≤ 5% C: 18 ... 32 VDC, max. perm. ripple ≤ 5% A: 18 ... 32 VDC, max. perm. ripple ≤ 5% AC (Note 2): 18 ... 32 VDC, max. perm. ripple ≤ 5% |
||||||||||||||||||
Current consumption | < 50mA |
||||||||||||||||||
Polarity protection | yes |
||||||||||||||||||
Cable length | I: max. 50m R / N (Note 1): max. 25m C: max. 50m A: max. 50m AC (Note 2): max. 50m |
||||||||||||||||||
Certificates | Class approval DNV |
||||||||||||||||||
Dimensions | Standard shaft length: 68 mm/ 138 mm (others on request), see drawing Connecting thread: outer thread G ¾ (inner thread G ¾ on demand) |
||||||||||||||||||
Notes | 1) R = Short circuit protected (SCP)/ N = Non-SCP; Only for HORN-Bearing Distance Monitoring System (BDMS) 2) Only in combination with GHG02088-5 |
Technical Specifications MPU010-I-K | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power supply | 8 ... 32 VDC, max. permissible ripple ≤ 5 % (protected by automatic fuse) 2 power supply inputs (redundancy) |
||||||||||||||||||
Power consumption | approx. 10 W |
||||||||||||||||||
Polarity protection | Yes |
||||||||||||||||||
Operating/ Storage temperature | -25 ... +85 °C |
||||||||||||||||||
Relative humidity | < 90 %, non-condensing |
||||||||||||||||||
Weight | Approx. 1000 g. |
||||||||||||||||||
Protection degree | IP 67 |
||||||||||||||||||
EMC-standard | DIN EN 55016 and DIN EN 55022, safety rules acc. EN 61000-4, -6 rules for type approval test accord. GL |
||||||||||||||||||
Connection to PE | Copper mesh band |
||||||||||||||||||
Cable glands | M12 for sensor |
||||||||||||||||||
Sensor interface | I2C |
||||||||||||||||||
Relays | PAV (pre-alarm-value), MAV (main-alarm-value), STATUS |
||||||||||||||||||
Analog output | current output or voltage output (details configurable: 4-20 mA or 0-10 VDC, others on request), galvanic isolated, user selectable |
||||||||||||||||||
Current output load | max.1200 Ω |
||||||||||||||||||
Ethernet | Transmission rate max. 100 Mbit/s, galvanic isolated, IP-Address adjustable |
||||||||||||||||||
CAN | Transmission rate 20 kBaud ... 1 Mbaud, galvanic isolated, Node ID adjustable 1...127 |
||||||||||||||||||
Configuration/ display | CAN open-protocol / Web page over ethernet |
Technical Specifications MPU010-I-G | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power supply | 8 ... 32 VDC, max. permissible ripple ≤ 5 % (protected by automatic fuse) 2 power supply inputs (redundancy) |
||||||||||||||||||
Power consumption | approx. 10 W |
||||||||||||||||||
Polarity protection | Yes |
||||||||||||||||||
Operating/ Storage temperature | -25 ... +85 °C |
||||||||||||||||||
Relative humidity | < 90 %, non-condensing |
||||||||||||||||||
Weight | Approx. 1000 g. |
||||||||||||||||||
Protection degree | IP 67 |
||||||||||||||||||
EMC-standard | DIN EN 55016 and DIN EN 55022, safety rules acc. EN 61000-4, -6 rules for type approval test accord. GL |
||||||||||||||||||
Connection to PE | Copper mesh band |
||||||||||||||||||
Cable glands | M12 for sensor |
||||||||||||||||||
Sensor interface | I2C |
||||||||||||||||||
Relays | PAV (pre-alarm-value), MAV (main-alarm-value), STATUS |
||||||||||||||||||
Analog output | current output or voltage output (details configurable: 4-20 mA or 0-10 VDC, others on request), galvanic isolated, user selectable |
||||||||||||||||||
Current output load | max.1200 Ω |
||||||||||||||||||
Ethernet | Transmission rate max. 100 Mbit/s, galvanic isolated, IP-Address adjustable |
||||||||||||||||||
CAN | Transmission rate 20 kBaud ... 1 Mbaud, galvanic isolated, Node ID adjustable 1...127 |
||||||||||||||||||
Configuration/ display | CAN open-protocol / Web page over ethernet |
Technical Specifications GHG02088-5 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power supply | 8 ... 32 VDC, max. permissible ripple ≤ 5 % (protected by automatic fuse) 2 power supply inputs (redundancy) |
||||||||||||||||||
Power consumption | approx. 2 W |
||||||||||||||||||
Polarity protection | Yes |
||||||||||||||||||
Operating/ Storage temperature | -25 ... +85 °C |
||||||||||||||||||
Relative humidity | < 90 %, non-condensing |
||||||||||||||||||
Weight | Approx. 700 g. |
||||||||||||||||||
Protection degree | IP 67 |
||||||||||||||||||
EMC-standard | DIN EN 55016 and DIN EN 55022, safety rules acc. EN 61000-4, -6 rules for type approval test accord. GL |
||||||||||||||||||
Connection to PE | Copper mesh band |
||||||||||||||||||
Cable glands | M16 for sensor |
||||||||||||||||||
Sensor interface | AC |
||||||||||||||||||
Relays | PAV (pre-alarm-value), MAV (main-alarm-value), STATUS |
||||||||||||||||||
Analog output | current output (4-20 mA), galvanic isolated |
||||||||||||||||||
Current output load | max. 500 Ω |