Technical Specifications Tacho-Indicator EA
Movement

Moving coil meter movements, current consumption 1 mA at full needle deflection; toe bearing and shock-proof pivot bearing resp., or toe bearing with spring-mounted jewels for extremely severe operating conditions

Needle- Scale

Needle black, dial white; graduations, inscription and figures conform to DIN 43802

Calibration

Normally carried out with reference to a HORN tacho-generator; measuring range and measured quantity can be selected at choice, i.e. any indicating (measuring) range can be assigned to any speed range of the  generator shaft

Reading accuracy

± 1% related to the scale length. With a wire cross section up from 2 x 0.75 mm2 , line lengths up to
100 m will not affect the indication. The temperature drift will not exceed 0.2% for each 10 °C change of temperature. These values conform to classification 1/0,2 (VDE 0410)

Temp. range

-20°… +45° C

Installation position

If not specified otherwise, indicators are calibrated for vertical mounting (position of the dial). Other mounting positions as per drawing below will be considered, provided the order specifies the angle of inclination of the scale with reference to the horizontal plane

Finish

Grey structure lacquer, with a seawater- and acid-proof enamel

Enclosure

IP 66

Electrical connection

Flat terminals to DIN 41000, flood-protected (enclosure IP 66). For the shipbuilding industry, the indicators are supplied with a screw cable gland M 24x1.5 (DIN 89280) instead of the Pg 7 gland

Type approval

Germanischer Lloyd

Scale illumination

24, 115 or 230 V; EA 106 ...available without scale illumination only, EA 107... can be operated with 24V only. The dial is transparent. The illumination can be adjusted or switched off by means of a dimmer DW 85 e (in separate box) or WIXG 122/... K (without box). The scale of indicators with clamp fixing can be illuminated indirectly by light slots

Calibration

To characteristic curve or table of customers; reading accuracy: ± 1.5 % related to full scale length

Adjustment

Should a readjustment of the indication be required, then this can be achieved via a potentiometer (DW) accessible on the rear of the casing. The potentiometer can be provided with a locking device (DWf) to prevent a displacement after the adjustment

Tropical protection

All indicators can be manufactured in tropicalized execution upon request

Special versions

Cover glass: non-reflecting or safety compound glass black dial with white graduations; pointer tip, main graduations, figures and measured quantity phosphorescent, scale ground after- glowing; graduations, figures, pointer and measured quantity black, scale with precise graduation, single or dual graduation; scale stretched in the initial or final range, zero hushed up to 25 % of final value (for 240° needle-deflection); dual or multiple scale by special calibration or additional graduation, coloured markings at any place of the scale, coloured sectors or bands, additional captions on scale

Technical Specifications Tacho-Indicator Form B, rectangular
Movement

Moving coil meter movements, current consumption 1 mA at full needle deflection, toe bearing

Needle

Needle black

Scale

Changeable scale, dial white; graduations, inscription and figures conform to DIN 43802.

Calibration

Normally carried out with reference to a HORN tacho-generator; measuring range and measured quantity can be selected at choice, i.e. any indicating range can be assigned to any speed range of the generator shaft. Furthermore it is possible to calibrate the indicator based on customer’s requirements or to the input values for
example 0...10 V or 0/4...20 mA. 

Adjustment

Should a readjustment of the indication be required, then this can be achieved via a potentiometer (DW) accessible on the rear of the casing

Reading accuracy

± 1,5% relative to the scale length: With a wire cross section up from 2x0.75 mm2 , line lengths up to 100m will not affect the indication. The temperature drift will not exceed 0.2% for each 10 °C change for temperature. These values are conform to classification 1.5/0.2 (VDE0410).

Temperature range

-20°C ... +70°C

Installation position

If not specified otherwise, indicators are calibrated for vertical mounting (position of the dial). Other mounting
positions as per drawing below will be considered, provided the order specifies the angle of inclination of the scale with reference to the horizontal plane.

Cover glass

non-reflecting mineral glas

Front frame

black acc. to DIN 43718

Housing

plastic material, dimension acc. to DIN 43700

Protection degree

Housing IP 54

Electrical connection

Terminals to DIN 46206 (enclosure IP00)

Type approval

available

Weight:
  • EA 72x72 ..sl-W =0,25kg
  • EA 96x96..sl-W =0,35kg
Scale length
  • EA 72 x 72 .. sl-W =103 mm
  • EA 96 x 96 .. sl-W =155 mm
Scale illumination

24V DC, adjustable by means of a dimmer (on request)