Logo
Technical specifications for Monitoring Unit MPU050x
Power supply

18 ... 32 VDC, max. permissible ripple ≤ 5 % (protected by automatic fuse)
2 power supply inputs (redundancy)

Power consumption

< 10 W

Polarity protection

Yes

Operating temperature

--25 ... +80 °C

Storage temperature

--25 ... +80 °C

Relative humidity

< 90 %, non-condensing

Protection degree

IP65

Weight

< 2,5 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Enviromental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Current output load

max. 1200 Ω

Ethernet

Transmission rate max. 100 Mbit/s, galvanic isolated, IP-Address adjustable

CAN

Transmission rate 20 kBaud ... 1 Mbaud, galvanic isolated, Node ID adjustable 1...127

Data access

Web page over ethernet, FTP

RTC battery

Lithium-thionyl chloride (Li-SOCl2), 1/2 AA, 3,6V

Connection to PE

Copper mesh band

Cable glands

M16 for sensor

M16 for serial

M16 for analog/binary inputs Cable size M16: ø6 ... 10.5 mm

M20 for power supply M20 for relay Cable size M20: ø8 ... 15 mm

Connectors
  • Ethernet: 1x M12x1, 4 pin D-coded (output), 4 pin connector (internal system)
  • CAN: 1x M12x1, 4 pin A-coded
Sensor interface

Ethernet

Sensor interface (additional)
  • I2C (Variant A)
  • RS422 (Variant B, BMS2 upgrade)
Cable length sensor inputs

Max. 100 m

Additional inputs
  • 2x Binary input (+24 VDC with own supply)
  • 2x Analog input (4-20 mA, others on request)
Output
  • 6x PhotoMOS Relay (Alarm) 
  • 1x PhotoMOS Relay (Ready)
  • 1x Mechanical Relay (Alarm)
  • 1x CAN (120 Ω resistor via switch)
  • 2x Analog output
  • 1x Serial output
  • 1x Ethernet output
Relays

Photo-MOS output: < 60 VDC, 500 mA (Short Circuit Protected SCP)

Analog output

Current output or voltage output (details configurable: 4- 20 mA, 0-20 mA, 0-24 mA or 0-SV, 0-10V VDC), galvanic isolated, user selectable

Serial output

RS422 / RS485, 9600, 19200, 38400, 57600 or 115200 baud, data printout, Modbus

Cable lengths

CAN: Usual CAN connection scheme applies
Ethernet: 100 m
Serial output: 50 m
Analog output: 30 m
Relay: 30 m

Configuration

Web page

Display

Web page, Modbus TCP

RTC setup

Web page, NTP

Technical specifications for the Sensor Box SBX01030x (3 cylinders)
Power supply

18 ... 32 VDC, max. permissible ripple ≤ 5 % (protected by automatic fuse)

Power consumption

< 5 W

Polarity protection

Yes

Operating temperature

-25 ... +85 °C

Storage temperature

-25 ... +85 °C

Relative humidity

<90 %, non-condensing 

Protection degree

IP65

Weight

< 2 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Enviromental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Connection to PE

Copper mesh band

Cable glands

M 12 for sensor
Cable size M12: (1)5 ... 6.5mm

Ethernet connector

1x M12x1, 8 pin X-coded (output, with power supply input)

Sensor interface

6xRS232, with 24 VDC sensor power supply, short circuit protected 8xl2C, with 5 VDC sensor power supply, short circuit protected

Cable length sensor inputs

Max. 15 m (others on request)

Analog output

Current output or voltage output (details configurable: 4-20 mA, 0-20 mA, 0-24 mA or 0-5V, 0-10V VDC), galvanic isolated, user selectable

Current output load

Max. 1200 Ω

Cable length ethernet

Max. 100 m

Cable length analog output

Max. 30 m

Ethernet

Transmission rate max. 100 Mbit/s, galvanic isolated, IP­-Address adjustable

Technical specifications for the Electronic Data Switch EDS00051 with power output
Power supply

18 ... 32 VDC, max. permissible ripples ≤ 5 % (protected by automatic fuse)
2 power supply inputs (redundancy)

Power consumption

< 5 W

Polarity protection

Yes

Operating temperature

-25 ... +85 °C

Storage temperature

-25 ... +85 °C

Relative humidity

< 90 %, non-condensing

Weight

< 2 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Enviromental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Connection to PE

Copper mesh band

Canle glands

M 12 for sensor
Cable size M12: (1)5 ... 6.5mm

Ethernet connector

1x M12x1, 8 pin X-coded (output, with power supply input)

Sensor interface

6xRS232, with 24 VDC sensor power supply, short circuit protected 8xl2C, with 5 VDC sensor power supply, short circuit protected

Cable length sensor inputs

Max. 15 m (others on request)

Analog output

Current output or voltage output (details configurable: 4-20 mA, 0-20 mA, 0-24 mA or 0-5V, 0-10V VDC), galvanic isolated, user selectable

Currrent output load

max. 1200 Ω

Cable length ethernet

Max. 100 m

Cable length analog output

Max. 30 m

Ethernet

Transmission rate max. 100 Mbit/s, galvanic isolated, IP­-Address adjustable

Technical specifications for Distance sensor IW000184
Power supply

15 ... 32 VDC, max. permissible ripple ≤ 5 %

Power consumption

< 1 W

Polarity protection

Yes

Operating temperature

-25 ... + 70 °C

Storage temperature

-25 ... + 85 °C

Relative humidity

< 90%, non-condensing

Protection degree

IP67

Weight

Approx. 0.12 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Environmental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Data interface

RS232

Connector

1x M12x1 4 pin A-coded, R5232 with 24 VDC power supply, short circuit protected

Cable length

Max. 15 m

Technical specifications for Water in Oil sensor FRG00035-I
Power supply

5 VDC, max. permissible ripple ≤ 5 %

Power consumption

< 0.25 W

Polarity protection

Yes

Operating temperature

-25 ... + 125 °C

Storage temperature

-25 ... + 1255 °C

Relative humidity

< 90%, non-condensing

Protection degree

IP67

Weight

Approx. 0.25 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Environmental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Data interface

I2C

Connector

1x M12x1 4 pin A-coded, R5232 with 24 VDC power supply, short circuit protected

Cable length

Max. 15 m (others on request)

Accuracy of humidity measurement

±3 % within -25 ... +85°C

Pressure resistance against medium

10 bar

Technical specifications for Temperature sensor TGL00922x
Power supply

5 VDC, max. permissible ripple ≤ 5 %

Power consumption

< 0.1 W

Polarity protection

Yes

Operating temperature

-40 ... + 125 °C (sensor)

-25 ... + 85 °C (cable)

Storage temperature

-25 ... + 85 °C

Relative humidity

< 90%, non-condensing

Protection degree

IP67

Weight

Approx. 0.1 kg.

EMC-standard

DIN EN 55016-2, safety rules acc. EN 61000-4, rules for type approval test accord. DNVGL-CG-0339

Environmental standard

DIN EN 60068-2 rules for type approval test accord. DNVGL-CG-0339

Data interface

I2C

Cable length

Max. 15 m (other on request)

Accuracy of temperature measurement

±0.5°C (typical from -20°C to 100°C)

Technical specifications for Cylinder liner temperature sensor TGL00942x
Element type

Type K, NiCr-NiAl

Operating temperature

max. 250°C (sensor)

-20°C. .. 85°C (signal converter box)

Max. temperature sensor tip

800 °C

Accuracy of temperature measurement

±2.5°C or 0.007*t (t = measuring value)

Weight

approx. 1 kg (unit)

Protection degree

IP65 (sensor and box)

Standards (converter box)

EMC accord. EN61000-4, vibration accord. DIN EN 60068-2

Technical specifications for Data Display EV325000
Power supply

+24 V DC (18 to 32 V DC)

Power consumption

< 21.6 W

Operating temperature

-10°C to +60°C

Weight

1.65 kg

Data interface

Ethernet

To top

Search