Technical Specifications
Tee Housing Material

Schedule 80 PVC

Insert Wetted Materials
  • Body: PPS (Ryton R-4)
  • Sensor: PEI (Ultem 1000)
  • O-Ring: EPDM

 

Temperature Rating
  • Operating: 32° F to 140° F (0° C to 60° C)
  • Storage: -20° F to +160° F (-29° C to +71° C)
Repeatability

Typically ± 0.03% of reading

Flow Range

0.1 to 15 fps (0.03 to 4.6 m/s)

Accuracy

Typically ±2% of reading

Operating Pressure
  • 203 psi @ 73° F (14 bar @ 23° C)
  • 150 psi @ 140° F (10 bar @ 60° C)
Transducer Excitation
  • Supply Voltage: 7.5V (dc) min. to 36V (dc) max
  • Quiescent Current: 200 μA (typical)
Output Frequency

0 to 100 Hz

Output Pulse Width

4 ms

Electrical Cable for Insert Electronics

36 inches (914.4 mm) of 18 AWG, solid copper, “Direct Burial” (UL 493 & 83)

Model/ Type
Product Identifier

QS200: QS200 Insertion Ultrasonic Flowmeter

Body Material
  • A: Aluminium
  • E: Extended flow Aluminium
  • M: Intermediate pressure aluminium
  • N: Intermediate pressure Stainless Steel
  • S: Stainless Steel
  • P: PPS (PPS rotors only, temp code 8, BSP/NPT, safe area only)
Meter Size
  • Blank Insert: Only 
  • -10: Schedule 80 PVC Tee – 1 inch 
  • -15: Schedule 80 PVC Tee – 1-½ inch 
  • -20: Schedule 80 PVC Tee – 2 inch 
  • -30: Schedule 80 PVC Tee – 2 inch
  • -40: Schedule 80 PVC Tee – 2 inch
NSF Certification
  • Blank: None
  • PW: Potable Water Version (NSF) - Not Available on Insert Only