Logo
Flomec OM Chemical 1024 Square

Oval Gear Chemical Flowmeters (OM series)

The Oval Gear Chemical Flow Meters from Flomec offers accurate volumetric flow measurement of a broad range of clean water-based products and aggressive chemicals. The Flowmeters are also suitable for most fuels, fuel oils, and lubricating liquids.

More advantages:

  • Direct volumetric reading, which gives high accuracy and repeatability
  • Measures liquids both of high and low viscosity
  • No requirements for flow conditioning

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

High accuracy and repeatability

The Oval gear meter is a precise positive displacement flowmeter incorporating a pair of
oval geared rotors. The meter is, therefore, independent of viscosity and density, which means that the same high accuracy is obtained regardless of changes in the physical parameters.

These meters can be used in gravity-fed application because of the high accuracy oval gear technology with low pressure drop.

Monitoring for precision

Oval Gear flowmeters are available as blind meters with a pulse signal output capable of
interfacing to most monitoring and control instrumentation.
Or the meter can be fitted with instruments such as totalizers, rate totalizers or batch controllers.

These instruments also have monitoring and control output options including 4-20mA, scaled pulse, flow-rate
alarms and batch control logic (preset metering).

Flomec OM Chemical 1024X16x9

Typical Applications

These PPS Flowmeters are used for;

  • Non-aromatic/non-halogenated organic chemicals
    Water-based liquids
  • Diesel Exhaust Fluid
  • Petroleum
  • Strong acids
  • Oxidizers.

Does it match your need - contact us here

Choose the right Flowmeter

The Oval Gear Meters use a measuring principle, where a pair of oval-shaped gears in a measuring chamber rotate by the force of the liquid on these. The liquid flows into a chamber and is sealed off once the chamber is full and produces either an electronic pulse or drives a gear to register the volume as it exits the chamber. 

As illustrated in the example on the right, the pulse is generated because the (green) liquid is sealed from both the inlet (red liquid) and exit (blue liquid). This set up would produce four pulses as the meter transmits four identical volumes for every cycle. 

Thus, it matters which Flowmeter you choose; because the simplest meters register each time a bucket is filled. Here the total volume would be the sum of the number of buckets filled. In the complex meters the discrete volumes passed each time can be summed together to see the overall volume passing through the meter.

See all Oval Gear Flow Meters here

Flomec OM Series Oval Gear Princip 1024X16x9
Flomec Q9 1 Display 1024X16x9

The Oval Gear Chemical Flowmeters has ceramic rotor pins as a standard, which makes it suitable for purposes where it does not suit or is permitted to use stainless steel.

Furthermore, the blind pulse meters are available with Reed Switch and Hall Effect outputs. You also have the option of quadrature pulse and integral 4-20mA outputs.

This means, that it can be used to either have dual resolution of the heart rate signal or as a backup.

Additionally, there is a wide selection of different LCD display types associated with this series, so you can get a display of the values ​​for instantaneous flow (eg l / h or m³ / h) and total flow (eg l or m³).

You also have the option to get a traditional mechanical display.

See all the accessories here

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Technical Specifications
Normal Size

1/2"(15 mm) - 4" (100 mm)

Nominal Flow Range* @ 3cP

0,26 GPM(1 L/min) - 660 GPM(2500 L/min)

Accuracy

±1% of reading for M registers.

±1% of reading for M registers (±0.5% for V registers)

Repeatability

Typically ± 0.03% of reading

Ambient Temperature Range

5° F - 176° F (-15° C to - 80° C)

Max. Pressure (threaded)

580 psi (40 bar) - 145 psi (10 bar)

M Register

4 digit resettable & NEMA 4 (IP65)

V Register

n/a

5 digit resettable & NEMA 3S (IP54)

Recommended Filtration

100 mesh (150 μm) - 40 mesh (400 μm)

Face-to-Face Dimension A - Threaded

4.33" (110 mm) - 12.6" (320 mm)

Face-to-Face Dimension A - Flanged

7.44"(189mm) - 16.3(414 mm)

Meter Base-to-Register Top - Dimension B

7.01"(178 mm) - 16.4" (416 mm)

Meter Cap Width

4.33" (110 mm) - 13.1" (332 mm)

Note

*Maximum flow reduces as viscosity increases. Max recommended Pressure drop is 14.5 psi (1 bar).

Model/ Type
Product Identifier
  • OM015: 1/2" (15mm) Oval Gear Meter, 1-40 L/min, 0.26-10.6 USG/min
  • OM025: 1" (25mm) Oval Gear Meter, 10-150 L/min, 2.6-40 USG/min
  • OM040: 1.5" (40mm) Oval Gear Meter, 15-250 L/min, 4-66 USG/min
  • OM050: 2" (50mm) Oval Gear Meter, 30-450 L/min, 8-120 USG/min
  • OM080: 3" (80mm) Oval Gear Meter, 35-750 L/min, 10-200 USG/min
  • OM080: 3" (80mm) Oval Gear Meter, 50-1000 L/min, 13-260 USG/min
  • OM100: 4" (100mm) Oval Gear Meter, 75-1500 L/min, 20-400 USG/min
  • OM100: 4" (100mm) Oval Gear Meter, 150-2500 L/min, 40-660 USG/min
Body Material
  • A: Aluminium
  • E: Extended flow Aluminium
  • S: 316L Stainless Steel
Rotor/ Bearing Material
  • 00: PPS
  • 10: High Viscosity PPS (not suitable for Temp code 3)
  • 44: Aluminium/Hardened Steel Roller Bearing (100E only)
  • 51: Stainless Steel / Carbon Ceramic Bearing
  • 71: High Viscosity Stainless Steel / Carbon Ceramic Bearing
Seal Material
  • 1: Viton (-15° C min. [5° F])
  • 3: Teflon Encapsulated Viton / Kalrez (-15° C min. [5° F])
  • 4: Nitrile (not suited Temp Code 3) (-40° C min. [-40° F])
Temperature Rating
  • 8: 80° C max. [176° F]
Process Connection
  • 0: No fittings (Flomec 4 bolt flange)
  • 1: BSPP (G) female threaded (ISO 228)
  • 2: NPT female threaded
  • 4: ANSI-150 RF flanged
         ANSI-150 RF flanged - SS Meters
  • 5: ANSI-300 RF flanged
  • 6: PN16 DIN flanged
         DIN flanged - SS Meters
Cable Entry
  • 0: None
Mechanical Display
  • M3: 4 digit mechanical totalizer - Litres
  • M4: 4 digit mechanical totalizer – US Gallons
  • V1: 5 digit mechanical reset register - Litres

Specifications & Manuals

  • Data Sheet - Oval Gear Mechanical Meter - Flomec
    English | pdf
  • Owners Manual - Oval Gear Mechanical Meter (OM015) - Flomec
    English | pdf
  • Owners Manual - Oval Gear Mechanical Meter (OM025 - 050E) - Flomec
    English | pdf
  • Owners Manual - Oval Gear Mechanical Meter (OM080 - 100E) - Flomec
    English | pdf
  • Data Sheet - Fuel Consumtion System Marine - Flomec
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search