Logo
EGM flowmeter Technical Specifications
Normal Size

1/8"(4 mm) - 3/4" (20 mm)

Flow range

Norminal Flow Range* @ 3cP: 0.26 GPH(1.0 L/hr) - 145 GPH(550 L/hr)
                                                    .26 GPM(1 L/min) - 21 GPM (80 L/min)

Flow Range @ 1cP: 0.25 GPH(2 L/hr) - 116.24 GPH(440 L/hr)
                                 0.39 GPM(1 L/min) - 16.91 GPM (64 L/min)

Flow Range @ 7cP: 0.13 GPH(0.5 L/hr) - 145.29 GPH(550 L/hr)
                                 0.13 GPM(0.5 L/min) - 21.13 GPM (80 L/min)

Flow Range @ 200cP: 0.10 GPH(0.4 L/hr) - 145.29 GPH(550 L/hr)
                                    0.10 GPM(0.4 L/min) - 21.13 GPM (80 L/min)

Flow Range @ 500cP: 0.06 GPH(0.25 L/hr) - 145.29 GPH(550 L/hr)
                                     0.08 GPM(0.3 L/min) - 26.42 GPM (80 L/min)

Flow Range @ 1000cP: 0,03 GPH(0.12 L/hr) - 95.10 GPH(360 L/hr)
                                        0.05 GPM(0.2 L/min) - 13.21 GPM (80 L/min)

Accuracy+

± 1% of reading (on the EGM004, EGM006 and EGM008) and ± 0.5 of reading (on the EGM015 and EGM020)

Repeatability

Typically ± 0.03% of reading

Ambient Temperature Range

5° F to +176° F (-15° C to +80° C)

Fluid Temperature Range

23˚F to +176˚F (-5˚C to +80˚C)

Max. Pressure (AI meters)

290 psi (20 bar) - 500 psi (34 bar)

Max. Pressure (SS meters)

290 psi(20 bar) - 800 psi (55 bar)

Protection Class

IP65

Recommended Filtration

200 mesh [75 μm] - 100 mesh [150 μm]

Pulse Output Type

NPN Open Collector (Hall Effect Sensor)

Voltage

5 - 24 V (dc)

Current Draw

20mA max.

Switching Current

10mA max.

Pulse Output Resolution - Standard Pulse/USG [Pulse/L]

398 [105] - 10600 [2800]

Pulse Output Resolution - Fuel Cons. Option Pulse/USG [Pulse/L]

99.5 [26.3] - 10600 [2800] 

RTD Specification (Integral Option 2)

Platinum Resistance Thermometer 100 Ohms (PT100) Class F0.3

Notes

*Maximum flow reduces as viscosity increases, see flow de-rating guide.
Max recommended Pressure drop is 14.5 psi (1 bar).


+When used to meter rate, at very low flow rates, the rate can jump, due
to resolution (not accuracy)

Model/ Type
Aluminium BSP Fuel Consumption Systems - For use on generators or transportation

FCS-06AB: 1/4" (6mm), BSPP (ISO 228). Includes: 2 x flow meters (EGM006A511-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets 4976.

FCS-08AB: 3/8" (8mm), BSPP (ISO 228). Includes: 2 x flow meters (EGM008A001-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets 4815.

FCS-15AB: 1/2" (15mm), BSPP (ISO 228). Includes: 2 x flow meters (EGM015A001-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers, mounting brackets 5243.

FCS-20AB: 3/4" (20mm), BSPP (ISO 228). Includes: 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets.

Aluminium NPT Fuel Consumption Systems - For use on generators or transportation

FCS-06AN: 1/4" (6mm), NPT. Includes: 2 x flow meters (EGM006A511-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets 4976.

FCS-08AN: 3/8" (8mm), NPT. Includes: 2 x flow meters (EGM008A001-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets 4815.

FCS-15AN: 1/2" (15mm), NPT. Includes: 2 x flow meters (EGM015A001-812), 1 x F127 temperature corrected totaliser, 2 x Y-strainers, mounting brackets 5243.

FCS-20AN: 3/4" (20mm), NPT. Includes: 1 x F127 temperature corrected totaliser, 2 x Y-strainers and mounting brackets.