Technical Specifications | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Normal Size | 1/8"(4 mm) - 3/4" (20 mm) |
||||||||||||||||||
Flow range | Norminal Flow Range* @ 3cP: 0.26 GPH(1.0 L/hr) - 145 GPH(550 L/hr) Flow Range @ 1cP: 0.25 GPH(2 L/hr) - 116.24 GPH(440 L/hr) Flow Range @ 7cP: 0.13 GPH(0.5 L/hr) - 145.29 GPH(550 L/hr) Flow Range @ 200cP: 0.10 GPH(0.4 L/hr) - 145.29 GPH(550 L/hr) Flow Range @ 500cP: 0.06 GPH(0.25 L/hr) - 145.29 GPH(550 L/hr) Flow Range @ 1000cP: 0,03 GPH(0.12 L/hr) - 95.10 GPH(360 L/hr)
|
||||||||||||||||||
Accuracy+ | ± 1% of reading (on the EGM004, EGM006 and EGM008) and ± 0.5 of reading (on the EGM015 and EGM020) |
||||||||||||||||||
Repeatability | Typically ± 0.03% of reading |
||||||||||||||||||
Ambient Temperature Range | 5° F to +176° F (-15° C to +80° C) |
||||||||||||||||||
Fluid Temperature Range | 23˚F to +176˚F (-5˚C to +80˚C) |
||||||||||||||||||
Max. Pressure (AI meters) | 290 psi (20 bar) - 500 psi (34 bar) |
||||||||||||||||||
Max. Pressure (SS meters) | 290 psi(20 bar) - 800 psi (55 bar) |
||||||||||||||||||
Protection Class | IP65 |
||||||||||||||||||
Recommended Filtration | 200 mesh [75 μm] - 100 mesh [150 μm] |
||||||||||||||||||
Pulse Output Type | NPN Open Collector (Hall Effect Sensor) |
||||||||||||||||||
Voltage | 5 - 24 V (dc) |
||||||||||||||||||
Current Draw | 20mA max. |
||||||||||||||||||
Switching Current | 10mA max. |
||||||||||||||||||
Pulse Output Resolution - Standard Pulse/USG [Pulse/L] | 398 [105] - 10600 [2800] |
||||||||||||||||||
Pulse Output Resolution - Fuel Cons. Option Pulse/USG [Pulse/L] | 99.5 [26.3] - 10600 [2800] |
||||||||||||||||||
RTD Specification (Integral Option 2) | Platinum Resistance Thermometer 100 Ohms (PT100) Class F0.3 |
||||||||||||||||||
Notes | *Maximum flow reduces as viscosity increases, see flow de-rating guide.
|
Model/ Type | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Identifier |
|
||||||||||||||||||
Materials of Construction |
|
||||||||||||||||||
Temperature Rating |
|
||||||||||||||||||
Process Connection |
|
||||||||||||||||||
Electrical Options | 1: Hall effect output (ISO 228) 2: Fuel Consumption (Pulsating flow Hall effect, PT100 temp. sensor) (2m cable) |