Logo
Technical Specifications
Normal Size:

1/8"(4 mm) - 3/8" (8 mm)

Process Connections:

3/8 in. NPT Elbows, 3x 90˚ orientation positions

Flow Range*:

0,26 - 145 GPH (1-550 L/hr)

*Maximum flow is to be reduced as viscosity increases, see flow de-rating guide.

Accuracy: @3cP

±1%

Repeatability:

0.25% reading

Temperature Range:

5˚ to 149˚ F (-15˚ to 65˚ C)

Max. Pressure (Static):

440 psi (30 bar)

Max. Pressure (Operating):

DC Solenoid Coils; 100 psi (7 bar)
AC Solenoid Coils; 295 psi (20 bar)

Hall Effect*:

AIM004: 10600 (2800)

AIM006: 3975 (1050)

AIM008: 2650 (710) 

*Electrical Output Resolution - Nominal Pulses per Gallon (Pulses / L)

High Resolution*:

AIM004: 42400 (11200)

AIM006: 15900 (4200) 

AIM008: n/a

*Electrical Output Resolution - Nominal Pulses per Gallon (Pulses / L)

Hall Effect Output (NPN):

3 wire open collector, 5 - 24V (dc) max, 20mA max

Protection Class:

IP66/67 (NEMA 4x); EXd I/II T3...T6

Model/ Type
Product Identifier

AIM: Additive Injection Manifold

Meter Size
  • 004: 1/8 in. (4 mm), 0.26-9.5 GPH (1-36 L/hr)
  • 006: 1/4 in. (6 mm), 0.5-27 GPH (2-100 L/hr)
  • 008: 3/8 in. (8 mm), 4-145 GPH (15-550 L/hr)
Seal Material
  • 1: FKM (Viton™) (standard for Alum.) -5º F minimum (-15º C)
  • 3: Chem-Kit, comprises Teflon & Perfluorelastomer (KalrezKemraz) O-rings -5º F minimum (-15º C)
Meter Protection Approval

1: IECEx / ATEX approved

Cable Entries
  • 1: M20 x 1.5 mm
  • 2: 1/2 in. NPT
Solenoid Valve Voltage
  • 1: 24V (dc) x 9W coil (maximum operating pressure 100 psi [7 bar])
  • 2: 110-115V (ac) / 60 hz x 8W coil (maximum operating pressure 295 psi [20 bar])
  • 3: 220-230V (ac) / 50 hz x 8W coil (maximum operating pressure 295 psi [20 bar])
Solenoid Valve Protection Approval

1: IECEx / ATEX approved coil

Solenoid Valve Orifice
  • 3: 3 mm (V (dc) coil = 100 psi [7 bar], V (ac) coil = 145 psi [10 bar] max. differential pressure)
  • 5: 5 mm (V (dc) coil = 50 psi [3.5 bar], V (ac) coil = 123 psi [8.5 bar] max. differential pressure)
Integral Options
  • 0: Hall Effect output
  • HR: High resolution Hall Effect output (Not available for AIM008)
To top